VRA_LD-30WR2 SERIES
30W, WIDE INPUT, ISOLATED & REGULATED
DUAL OUTPUT DC-DC CONVERTER
FEATURES
● Efficiency up to 89%
● 2:1 wide input voltage range
● Operating temperature range:
-40°C ~ +85°C
● 1.5KVDC isolation
● Output short circuit , over current and over voltage
protection
● Meet CISPR22/EN55022 CLASS A
● Industry standard pinout
● Inverse polarity protection for A2S(chassis
mounting)and A4S(DIN-Rail mounting)
APPLICATION
The VRA_LD-30WR2 series offer 30W of output, with 2:1 wide input
voltage of 18-36VDC, 36-75VDC and features 1500VDC isolation, over
current and short-circuit protection etc, as well as six-sided metal
shielding. All models are particularly suited to industrial control, electric
power, instrumentation, tele-communications etc.
Patent Protected RoHS
PART NUMBER SYSTEM
VRA2405LD-30WR2
Rated Power
Package Style
Output Voltage
Input Voltage
Product Series
SELECTION GUIDE
③
Input Voltage (VDC)
Output Current (mA) Input Current (mA)(typ.)
@
Output
Voltage
(VDC)
reflection
ripple Current
(mA,typ.)
Max.
Capacitor
Load (max,µF)
Efficiency
(%, typ.)
①
Nominal
Model Number
②
Max.
Min.
@ No load
Max
(Range)
Max.load
@ Max. load
VRA2405LD-30WR2
VRA2409LD-30WR2
VRA2412LD-30WR2
VRA2415LD-30WR2
VRA2424LD-30WR2
VRA4805LD-30WR2
VRA4812LD-30WR2
VRA4815LD-30WR2
VRA4824LD-30WR2
±5
±9
±3000
±1667
±1250
±1000
±625
±150
±83
±63
±50
±32
±150
±63
±50
±32
±3000
±470
±470
±470
±300
±3000
±470
±470
±300
88
88
88
89
89
88
89
89
89
1460
120
20
20
20
20
80
20
20
20
20
10
10
10
10
20
10
10
10
1440
1440
1440
1440
730
24
40
±12
±15
±24
±5
(18-36)
±3000
±1250
±1000
±625
±12
±15
±24
720
48
80
(36-75)
720
720
Note: ① series with suffix “H” are heat sink mounting, for example VRA2405LD-30WHR2. series with suffix "A2S" are chassis mounting, with suffix "A4S" are DIN-Rail
mounting, for example VRA2405LD-30WR2A2S is chassis mounting, VRA2405LD-30WR2A4S is DIN-Rail mounting. If the application has a higher requirement for
heat dissipation, you can choose modules with heat sink.
②Absolute maximum rating without damage on the converter, but it isn't recommended.
③The efficiency of "A2S" and "A4S" is approx. 2% lower for the protection of inverse polarity.
INPUT SPECIFICATIONS
Item
Test conditions
Min.
Typ.
Max.
Unit
24VDC Input Models
48VDC Input Models
24VDC Input Models
48VDC Input Models
24VDC Input Models
48VDC Input Models
Nominal input & constant resistance load
-0.7
-0.7
--
--
50
Input Surge Voltage (1sec. max.)
100
VDC
--
--
17.8
35.8
--
18
36
--
Start-up Voltage
16
32
Under Voltage Shutdown
Start-up Time
VDC
ms
--
--
--
10
--
The copyright and authority for the interpretation of the products are reserved by MORNSUN
VRA_LD-30WR2
2013.09.24-A/0
Page 1 of 7