rev.
1 of 4
page
page
date
date
02/2010
PART NUMBER: VOF-80
DESCRIPTION: switching power supply
features
• no-load power consumption < 0.5W
• universal input 85~264 V ac
• over current, over voltage protected
• industry standard footprint
• efficiency up to 89%
• safety approved to CB, TUV, CE, UL/cUL
• conducted EMI meets EN55022 class B and FCC class B
4
1,2
3
MODEL
output voltage
output current total regulation
ripple & noise
efficiency
(V dc)
3.3
5
(A)
10
(%)
±5
±5
±5
±5
±5
±5
(mVp-pmax.)
120
(%)
75
76
85
86
87
89
VOF-80-3.3
VOF-80-5
10
120
VOF-80-12
VOF-80-15
VOF-80-24
VOF-80-48
12
6.66
5.33
3.33
1.66
120
15
150
24
240
48
480
notes:
1. Measured from high line to low line at rated load.
2. Measured from full load to 10% load at 115 V ac.
3. Ripple & noise are measured at 20MHz bandwidth with 0.1 µf ceramic & 10 µf electrolytic capacitors on the output.
The two earth ground pads are connected to input earth ground.
4. See derating curves
INPUT
parameter
conditions/description
min
47
nom
max
63
units
Hz
input frequency
input voltage
input current
output power derated from 85-90 V ac
AC input of 110 V ac
85
264
V ac
mA
mA
A
1500
800
AC input of 220 V ac
inrush current
input fuse
AC input of 110 V ac, full load, cold start
AC input of 220 V ac, full load, cold start
built-in, non-user serviceable
25
50
A
OUTPUT
parameter
efficiency
conditions/description
min
nom
max
units
see table above, typical values measured
at 115 V ac, full load
hold up time
at 115 V ac, full load
8
mS
%
adjustability
-10
+5
temp. coefficient
-0.05
+0.05
%/°C
PROTECTION CIRCUIT
parameter
conditions/description
output overload
current limiting starts at 105% of the rated output current and recovers automatically
output over voltage output voltage is limited by TVS clamping to: 6.8 V for 3.3 & 5 V models, 135% for all other models
output short circuit protected, long-term short circuit may reduce reliability
th
20050 SW 112 Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383 www.v-infinity.com