12 1-800-735-6200
BatMod Specifications
BatMod™
(typical TBP = 25°C, nominal line, 75% load, unless otherwise specified)
Battery Charger
Parameter
Nominal Input Voltage
Remarks
48Vdc, 150Vdc,
300Vdc
42-60V, 100-200V,
200-400V
Current Source Modules
Output Current
(Refer to Safe Operating
Curves below)
Current Control Input
Current Monitor Output
Voltage Control Input
Output Voltage Setpoint
Trimmable +10%, -25%
Dynamic Characteristics
0-14.5A
12V battery system
24V battery system
48V battery system
Zero to max. current
Zero to full load
Zero to FS output
12V, 24V, 48V
0-7.25A
Features
0-3.6A
ꢀ Programmable Output Current
ꢀ Booster Versions Available
ꢀ Size: 4.6" x 2.4" x 0.5"
(116,8 x 61,0 x 12,7)
1V to 5V
1V to 5V
0V to 2.5V
15V, 30V, 60V +/-1%
Output Respectively
ꢀ UL, CSA, TÜV
ꢀ Compatible with All Major
Battery Types
ꢀ Inputs: 48, 150, 300Vdc
ꢀ Outputs: 12, 24, 48Vdc Nom.
ꢀ Analog Current Monitor
ꢀ Analog Overvoltage Adjust
ꢀ CE Marked
V Mode: 300 µsec typ.
I Mode: 250 µsec typ.
VNOM for 50-100%
load changes
Operating Temp./Storage Temp.
-10°C to +85°C, -20°C to +100°C
-25°C to +85°C, -40°C to +100°C
-40°C to +85°C, -55°C to +100°C
-55°C to +85°C, -65°C to +100°C
Dielectric Withstand
E-Grade
C-Grade
I-Grade
M-Grade
Input to Output
3,000VRMS
500VRMS
1,500VRMS
Output to Baseplate
Input to Baseplate
Product Highlights
The BatMod combines Vicor’s industry
standard package with the flexibility of
a power converter whose output voltage
and output current may be independently
set. BatMod’s allow the user to
independently program a constant output
current and a maximum float voltage.
The float voltage is the point at which
the BatMod transitions from constant
current to constant voltage. These
features make the BatMod an ideal
candidate for battery charging and other
applications which require a controlled
current source.
Safe Operating Conditions
Current
Power Current
Exceeded Exceeded
Power
Current
Exceeded Exceeded
Power
Exceeded
Exceeded
High Program
Exceeded
High Program
Exceeded
High Program
Exceeded
36
32
28
24
20
16
12
8
72
18
16
14
12
Maximum
Voltage
Maximum
Voltage
Setpoint
16.5V
33.0V
Maximum
Voltage
Setpoint
66.0V
64
56
Setpoint
Safe Operating Area
Safe Operating Area
Safe Operating Area
27.6V
13.8V
55.2V
48
40
32
24
16
Minimum
Voltage
Setpoint
22.5V
Minimum
Voltage
Setpoint
Minimum
Voltage
Setpoint
11.25V
6.9V*
45.0V
10
8
Minimum
Operating
Voltage
Minimum
Operating
Voltage
Minimum
Operating
Voltage
13.8V*
27.6V*
6
4
2
4
8
2
4
6
8
10 12 14 16
1
2
3
4
5
6
7
8
0.5
1
1.5
2
2.5
3
3.5
4
Amps
Amps
Amps
14.5A
7.25A
3.6A
12V Battery System
24V Battery System
48V Battery System
*Maximum recommended battery discharge.
The BatMod is also available in booster
versions that enable the designer to
create systems capable of multiple
kilowatts of output power.
Part Numbering
Typical Model:
V I - 2 6 1 - E U - B M
Input: 300Vdc
Output: 12Vdc at 200W
With its wide range of input options, the
BatMod is compatible with all major
battery types. This new current output
module finds application in systems
where easily programmable current is of
primary importance.
Module
Input Voltage
Output Voltage
Product Grade
Nominal
Range
Nominal
Range
E = -10°C to +85°C
C = -25°C to +85°C
2
B
=
=
Driver
Booster
3 = 48V 42 - 60V
5 = 150V 100 -200V
6 = 300V 200 -400V
1 = 12V (11.25-16.5V)
3 = 24V1 (22.5-33.0V)
4 = 48V (45.0-66.0V)
I
= -40°C to +85°C
M = -55°C to +85°C
Consult factory for availability of
input/output voltage ranges not shown.
1. Available in 300V input only.
Packaging Options:
SlimMod™, high power density, flangeless packages and FinMods™, featuring integral
finned heatsinks.
SlimMod: Add the suffix -S to the end of the BatMod part number.
FinMods: Add the suffix -F1 for .25"H Longitudinal Fin; F2 for .5"H Longitudinal Fin
-F3 for .25"H Transverse Fin; F4 for .5"H Transverse Fin