VI 200
5 0 - 2 0 0 W P C B M O U N T I N G C O M P O N E N T S
Features
•
•
•
•
•
•
•
Inputs: 10 to 400VDC
Output, 1 to 95VDC
UL, CSA, TÜV, VDE, BABT, CF
80–90% efficiency (typical)
ZCS power architecture
Low noise FM control
Booster versions available for expanded power
Specifications
Selection Table
INPUT
A = INPUT VOLTAGE
B = OUTPUT VOLTAGE
Input voltage
See table
Nominal
0= 12V
1= 24V
W= 24V
2= 36V
3= 48V
N= 48V
4= 72V
T= 110V
5= 150V
6= 300V
Range Notes
10–20V (1)
21–32V (6)
18–36V (4)
21–56V (3)
42–60V (6)
36–76V (6)
55–100V (6)
66–160V (4)
100–200V (5)
200–400V (6)
OUTPUT
Z = 2V
Y = 3.3V
0 = 5V
2 = 15V
N = 18.5V
3 = 24V
L = 28V
J = 36V
K = 40V
4 = 48V
H = 52V
F = 72V
D = 85V
B = 95V
PRODUCT GRADE
Output voltage
Output power
E, C, I, M
See table
See table
0.5%
X = 5.2V
W = 5.5V
V = 5.8V
T = 6.5V
R = 7.5V
M = 10V
1 = 12V
P = 13.8V
Set point accuracy
Low–high trim voltage
Output ripple pk-pk
Load regulation
Line regulation
OVP set point
50%–110%
1%
0.05%
0.05%
7= 150/300V 100–375V (2)
115%–135%
105%–125%
C = PRODUCT GRADE D = OUTPUT POWER/CURRENT
Current limit setting
V out ≥5V
Y= 50W
V out <5V
Y= 10A
Remote sense Compensation0.5V
E= -10°C to +85°C
C= -25°C to +85°C
I= -40°C to +85°C
M= -55°C to +85°C
OPERATING
X= 75W
X = 15A
W = 20A
V = 30A
U = 40A
W= 100W
V= 150W
U= 200W
MTBF
>1,000,000 hrs
Efficiency
80%–90%
3750V rms
Isolation input – output
NOTES:
Baseplate operating temp. 85°C
NOTES: Maximum Output for — (1)
(2)
(3)
(4)
(5)
(6)
Shutdown temperature
Thermal shutdown
ENVIRONMENTAL
Cooling
95°C
5V Outputs
>5V Outputs
<5V Outputs
75W 75W* 100W 150W 150W 200W
75W 100W 100W 150W 200W 200W
15A 20A 20A 30A 40A 40A
Yes, C, I, M grades
*100W @ 5V (20A), 300V input only.
External cooling often required, consult sales
office
STANDARDS AND APPROVALS
Safety
UL1950, CSA C22.2 No. 950, TÜV IEC950,
EN60950, VDE 0805
C-Tick
AS/NZS CISPR11 Group 1 Class A
MECHANICAL
Dimensions
PCB mounting
117x61x12.7mm
Yes
Selection Table Guide
VI - 2 [a] [b] - [c] [d]
VI - B [a] [b] - [c] [d] Booster
Note: For RoHS version replace VI with VE.
Mechanical Drawings See page 230
Your dependable power partner – www.powerbox.com.au
229