xppower.com
150 Watts
VFT Series
•
•
•
•
•
•
•
100 W Convection Rating
150 W Forcedꢀcooled Rating
3” x 5” Package
Single Outputs from 5 V to 48 V
Builtꢀin Fan Supply
<0.5 W No Load Input Power
Low Cost
B R A N D
GREEN•POWER
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• 90-264 VAC
• 47-63 Hz
• 2.5 A max at 115 VAC, 1.5 A max at
230 VAC
Efficiency
Isolation
• Up to 92ꢀ, see table
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VDC Output to Ground
Switching Frequency
MTBF
• PFC: 45-80 kHz, PWM: 100-115 kHz
• >300 kHrs to MIL HDBK 217F at
25 °C, GB
Inrush Current
• 80 A max at 230 VAC, cold start 25 °C
Earth Leakage Current • 180 µA max at 230 VAC/50 Hz
Power Factor • >0.9 at 230 VAC and full load
No Load Input Power • <0.5 W
Environmental
Input Protection
• Internal T3.15 A/250 V fuse in line
Operating Temperature • -10 °C to +70 °C derate from 100ꢀ load
at 50 °C to 50ꢀ load at 70 °C for 12, 24 &
Output
48 V versions or 65 °C for 5 & 15 V versions
Cooling
• Convection-cooled: 100 W
Forced-cooled: 150 W
(120 W for 5 V models) with 15 CFM
• 5ꢀ to 90ꢀ RH, non condensing
• 3000 m
Output Voltage
• See table
• None
Output Voltage Trim
Initial Set Accuracy
Minimum Load
•
2ꢀ at 50 ꢀ load
Operating Humidity
Operating Altitude
• No minimum load requirement
• 2 s max
• 35 ms typical
Start Up Delay
Storage Temperature • -20 °C to +85 °C
Shock
Start Up Rise Time
Hold Up Time
• IEC68-2-6, 30 g, 11 mins half sine, 3 times
in each of 6 axes
• IEC68-2-27, 10-55 Hz, 2 g 10 mins /
sweep. 60 mins for each of 3 axes
• 8 ms minimum at full load and 115 VAC
Line Regulation
Load Regulation
Transient Response
•
•
0.5ꢀ max
0.5ꢀ max
Vibration
• 5ꢀ maximum deviation, recovering to less
than 1ꢀ within 500 µs for 50ꢀ step load
• 5 V version: 85 mV pk-pk max,
1ꢀ pk-pk max for others (see note 1)
EMC & Safety
Ripple & Noise
Emissions
• EN55022, level B conducted & radiated
• EN61000-3-2 class A
EN61000-3-2 class C for loads ≥60 W
• EN61000-3-3
• EN61000-4-2, 8 kV air, 4 kV contact,
Perf Criteria A
• EN61000-4-3, 3 V/m, Perf Criteria A
• EN61000-4-4, level 3, Perf Criteria A
• EN61000-4-5, installation class 3,
Perf Criteria A
Harmonic Currents
Overvoltage Protection • 110-135ꢀ, recycle input to reset
Overload Protection • 130-160ꢀ
Short Circuit Protection • Trip and restart (hiccup mode)
Temperature
Coefficient
Voltage Flicker
ESD Immunity
• 0.02 ꢀ/°C
Radiated Immunity
EFT/Burst
Remote Sense
Fan Supply
• Compensates for 0.5 V total voltage drop
• 5 V version: 5 V at 200 mA
Other versions: 12 V at 300 mA
Surge
Conducted Immunity
Dips & Interruptions
• EN61000-4-6, 3 V, Perf Criteria A
• EN61000-4-11, 30ꢀ 10 ms,
60ꢀ, 100 ms, 100ꢀ, 5000 ms
Perf Criteria A, B, B
Safety Approvals
• UL60950-1, IEC60950-1, EN60950-1