xppower.com
60 Watts
VEH Series
•
•
•
•
•
•
•
Energy Efficiency Level V, ≥15 V
CEC 2008 & EISA 2007 Compliant
China Compulsory Certfication (CCC) Qualified
Single Outputs from 12 V to 30 V
Optional Inlet Connectors
No Load Input Power <0.5 W
High Power Density
B R A N D
Specification
Input
General
Input Voltage
Input Frequency
Input Current
Inrush Current
• 90-264 VAC
• 47-63 Hz
• 1.7 A max
• 50 A max at 230 VAC, cold start at 25 °C
Efficiency
• See table
• Level V ≥15 V
• 3000 VAC Input to Output,
1500 VAC Input to Ground.
Energy Efficiency
Isolation
Switching Frequency
MTBF
• 60 kHz 10 kHz
• >700 kHrs to Bell Core iss. 6
Earth Leakage Current • <1 mA at 240 VAC/50 Hz
Power Factor • EN61000-3-2, class A
No Load Input Power • <0.5 W
Input Protection
• Internal T3.15A/250 V fuse in line
Environmental
Operating Temperature • 0 ˚C to +60 ˚C derate linearly from 100%
load at +40 ˚C to 50% load at +60 ˚C
Storage Temperature • -20 ˚C to +85 ˚C
Output
Output Voltage
• See table
Initial Set Accuracy
Minimum Load
•
5% at 50% load
Operating Humidity
Storage Humidity
Shock
• 5% to 90% RH non-condensing
• 5% to 95% RH non-condensing
• 6 random drops from 0.7 m with no
• No minimum load requirement
• 8 ms min at 115 VAC, full load
• 3 s max
Hold Up Time
Start Up Delay
damage, 50 g for 20 ms in each of 3 axes
Start Up Rise Time
Transient Response
• 8 ms typical
Vibration
• 2 g variable frequency from 20 Hz to 30 Hz
• 4% maxiumum deviation, recovering to
less than 1% within 500 µs for a 50%
step load change
EMC & Safety
Line Regulation
Load Regulation
Ripple & Noise
•
•
0.5% max
5% max
Emissions
• EN55022, level B conducted & radiated
• EN61000-3-2 class A
• EN61000-3-3
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
• 200 mv pk-pk max, 20 MHz bandwidth
(see note 1)
Overvoltage Protection • See table
Overload Protection • 110 -180%
Short Circuit Protection • Continuous (hiccup/trip & restart mode
with auto recovery)
0.04%/˚C
Surge
• EN61000-4-5, installation class 3,
Perf Criteria B
Temperature
Coefficient
•
Conducted Immunity
Magnetic Field
• EN61000-4-6, level 2 Perf Criteria A
• EN61000-4-8, 3 A/m Perf Criteria A
Dips & Interruptions
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms Perf Criteria A, B, B
Safety Approvals
• IEC60950-1, EN60950-1, UL/cUL60950-1,
China Compulsory Certification (CCC)
qualified, Approved as Limited Power
Source