xppower.com
90 Watts
VEH Series
•
•
•
•
•
•
•
Energy Efficiency Level V
CEC 2008 & EISA 2007 Compliant
High Power Density
Single Outputs from 12 V to 24 V
No Load Input Power <0.5 W
Optional Output Connector
Low Cost
B R A N D
Specification
Input
General
Input Voltage
Input Frequency
Input Current
Inrush Current
• 90-264 VAC
• 47-63 Hz
• 1.5 A max at 90 VAC
• 110 A max at 230 VAC, cold start at 25 °C
Efficiency
• See table
• Level V
• 3000 VAC Input to Output,
1500 VAC Input to Ground
PS12: 500 VDC Output to Ground,
PS19/24: Negative output is connected to
Ground
Energy Efficiency
Isolation
Earth Leakage Current • <1 mA at 230 VAC/50 Hz
Power Factor • >0.95 at 230 VAC and full load
No Load Input Power • <0.5 W
Switching Frequency
MTBF
• PFC: 25-125 kHz, PWM: 60 kHz typical
• >160 kHrs to Bell Core iss. 6
Input Protection
• Internal T2.0A/250 V fuse in line
Environmental
Output
Operating Temperature • 0 °C to +60 °C derate linearly from 100%
load at +40 °C to 50% load at +60 °C,
Storage Temperature • -10 ˚C to +85 °C
Output Voltage
• See table
Initial Set Accuracy
Minimum Load
•
5% at 50% load
• No minimum load requirement
• 10 ms min at 115 VAC, full load
• 3 s max
Operating Humidity
Storage Humidity
Shock
• 5% to 90% RH non-condensing
• 5% to 95% RH non-condensing
• 6 Random drops from 0.7 m with no
damage, 50 g for 20 ms in each of 3 axes
Hold Up Time
Start Up Delay
Start Up Rise Time
Transient Response
• 8 ms typical
• 4% maxiumum deviation, recovering to
less than 1% within 500 µs for a 50%
step load change
Vibration
• 2 g variable frequency from 20 Hz to 30 Hz
Line Regulation
Load Regulation
Ripple & Noise
•
•
0.5% max
5% max
EMC & Safety
Emissions
• EN55022, level B conducted & radiated
• EN61000-3-2 class A,
• 1% pk-pk max, 20 MHz bandwidth
(see note 1)
Harmonic Currents
EN61000-3-2 class C >60% load
• EN61000-3-3
Overvoltage Protection • See table
Overload Protection • 120 -180%
Short Circuit Protection • Continuous (hiccup/trip & restart mode
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, installation class 3,
Perf Criteria A
with auto recovery)
Temperature
Coefficient
•
0.04%/°C
Surge
Conducted Immunity
Magnetic Field
• EN61000-4-6, level 2 Perf Criteria A
• EN61000-4-8, 3 A/m Perf Criteria A
Dips & Interruptions
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
Safety Approvals
• EN60950-1:2001, UL/cUL60950-1