AC-DC Power Supplies
VCE03 Series
3 Watts
• Ultra Compact SIL Package
• Single Outputs from 3.3 to 48VDC
• PCB Mount
• Encapsulated & Open Frame
• 85 to 305VAC Input
• ITE & Household Appliance Approvals
• Class II
• <0.3 W No Load Input Power
• Low Cost
GREEN
POWER
Dimensions:
• 3 Year Warranty
VCE03:
1.60 x 0.75 x 0.75” (40.6 x 19.10 x 19.10 mm)
VCE03-P:
The VCE03 is a series of open frame and encapsulated AC-DC single output power supplies
designed for low cost ITE industrial and domestic applications. The series provides two mechanical
options including open frame and encapsulated PCB mount. With approvals to world-wide safety
standards including ITE and household, compliance with class B for conducted and radiated
emissions, these class II isolation parts benefit system designers with easy integration into a wide
range of applications.
1.50 x 0.65 x 0.65” (38.1 x 16.5 x 16.5 mm)
Models & Ratings
Output Power
Output Voltage
Output Current
Model Number (1)
3 W
3 W
3 W
3 W
3 W
3 W
3 W
3.3 VDC
5.0 VDC
9.0 VDC
12.0 VDC
15.0 VDC
24.0 VDC
48.0 VDC
910 mA
600 mA
333 mA
250 mA
200 mA
125 mA
63 mA
VCE03US03
VCE03US05
VCE03US09
VCE03US12
VCE03US15
VCE03US24
VCE03US48
Notes
1. For Open Frame version add suffix -P to model number, e.g. VCE03US12-P.
Summary
Characteristic
Input Voltage Range
No Load Input Power
Efficiency
Minimum
Typical
Maximum
305
Units
VAC
W
Notes & Conditions
85
Derate from 100% at 90 VAC to 90% at 85 VAC
0.3
80
%
Model dependant
Operating Temperature
EMC
-25
+70
°C
Derate linearly from 100% at +50 °C to 50% at +70 °C
EN55032 Level B Conducted & Radiated, EN601000-3-2, EN61000-3-3, EN55024
IEC62368-1, IEC60335-1, IEC60950-1, EN62368-1, EN60335-1, UL62368-1
Safety Approvals
Input
Characteristic
Minimum
Typical
Maximum
305
Units
Notes & Conditions
Covers all standard voltages in range from 100 VAC to
277 VAC
Input Voltage Range
85
47
VAC
Input Frequency
63
Hz
A rms
W
Input Current - Full Load
No Load Input Power
Inrush Current
Earth Leakage Current
Input Protection
0.10/0.06/0.04
At 115/230/277 VAC
0.3
40/44.2
A
At 230/277 VAC, cold start 25 °C
Class II construction no earth
External T1.0 A/300 VAC fuse required in line
www.xppower.com
1