Signal Relays
AXICOM
Reed Relay V23100 -V4
n
n
n
n
n
Direct coil control with TTL-signals possible
Highly reliable switching
High switching rates
Ultrasonic cleanable
High vibration and shock resistance
Typical applications
Incircuit tester, measuring and control systems, telecom equipment, alarm
and security equipment
Z
Approvals
Coil Data (continued)
UL File No. 111441
Coil versions, limiting operate voltage
Technical data of approved types on request
Coil
DIP flat,
SIL,
DIP flat DIP high DIP high DIP high Mini SIL
1 form A 1 form C 2 form A 1 form C 1 form A
code
Contact Data
form A
form C
1 form A with diode
std,diode diode+
shield
Contact arrangement
1 form A (1 NO),
2 form A (2 NO)
1 form C (CO)
VDC
22.0
33.0
44.0
44.0
VDC
14.0
25.0
47.0
47.0
VDC
13.0
22.0
44.0
44.0
VDC
14.0
25.0
47.0
47.0
VDC
14.5
23.5
14.5
49.0
VDC
13.6
21.6
-
Max. switching voltage
at rated coil voltage 5VDC
at rated coil voltage 12to 24VDC 200VDC/VACpeak
Limiting continuous current
Switching power
05
12
15
24
200VDC/VACpeak
175VDC
175VDCpeak
1.2A
1A
-
All figures are given for coil without pre-energization, at ambient temperature +23°C
10W, 10VA
3W, 3VA
Contact material
Contact style
Initial contact resistance
Operate / release time max.
Electrical endurance
at 12V/10mA
Ruthenium
reed contact
<150mΩ
0.75/0.15ms
1.1/1.6ms
50x106 operations
5x106 operations
at 24V/400mA
Coil Data
Magnetic system
Coil voltage range
Max. coil temperature
Thermal resistance
neutral
5 to 24VDC
105°C
< 75K/W
Coil versions, monostable
Coil
Rated
voltage
VDC
Operate
voltage
VDC
Release
voltage
VDC
Coil
resistance
Ω 10ꢀ
Rated coil
power
mW
code
1 form A (1 NO) contact
05
12
15
24
5VDC
12VDC
15VDC
24VDC
3.5
8.4
10.5
16.8
0.75
1.80
2.25
3.60
500
50
1000
2000
2000
144
112
288
Ambient temperature tamb [°C]
2 form A (2 NO) or 1 form C (1 CO) contact
Coil operative range
Coil operative range graphs
05
12
15
24
5VDC
12VDC
15VDC
24VDC
3.5
8.4
10.5
16.8
0.75
1.80
2.25
3.60
200
500
2000
2000
125
288
112
288
UI
Minimum voltage at 23°C after pre-energizing with rated voltage
without contact current
UII
Maximum continous voltage at 23°C
The operating voltage limits UI and UII depend on the temperature according to
the formula:
All figures are given for coil without pre-energization, at ambient temperature +23°C.
UI tamb KIxUI 23°C and
UII tamb KIlxUIl 23°C
tamb
Ambient temperature
UI tamb Minimum voltage at ambient temperature, tamb
UII tamb Maximum voltage at ambient temperature, tamb
KI , KII Factors (dependent on temperature), see diagram
1
08-2011, Rev. 0811
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company