Filling level probe
Level Monitors Type NS
The NS level monitor is an elec-
Application:
General
tronical device for monitoring
liquidlevels.Theycanbeusedas
limit monitor or minimal-maximal
control.
The monitoring of liquid levels is
effected via electrodes.
The NS units protect aggregates and plants against dry
running, overflow, leakage damages and unnecessary
lost of liquids. Characteristical applications are swim-
mingpools,groundwaterendangeredbuildings,oilfilled
under-water-pumpsaswellaswhereeveracertainlevel
should be maintained resp. dosed.
The level capture is effected
The level monitor operates as conductivity measuring
device and guarantees a perfect level capture at a
resistance of up to 250 kΩ, measured between the
electrodes.ZIEHLlevelmonitorsarealsoavailablewith
adjustable time delay in order to avoid a too high relay
switching frequency in case of a moving water surface.
Aselectrodesanyconductors,thatjutintothetankdown
to the required level, can be used. At metal tanks the
wall of the tank can be used as basic electrode.
Function
throughresistancemeasurement
via an AC voltage measuring
path, operating completely DC
voltage-free. Hereby, the resis-
tance between two (resp. three)
electrodes is measured.
When the level increases, the
electrodes are bridged and an
integrated relay switches.
Niveauelectrodes
Behälterwandung
Insulated screw-in electrodes for mounting in walls of
tanks.Theelectrodesaremadeofstainlesssteel(V2A),
the material of the insulation is Teflon.
Electrode NE1
2 Scheiben
Schraube
M4x20 V2A
2 Muttern
Part number:
V223430
The electrode NE2 with its ½"
thread can directly be screwed
into the wall of a tank. The two
electrodes (stainless steel V4A)
are flush cast in a plastic housing
(Polypropylen, PP) with cast re-
sin. The electrode can be used in
a temperature-range -5…105 °C
and is pressure-resistant up to 6
bar. The ingrained cable with 2
strands, each 0,25 mm2, is 2000
mm long, Ø 4 mm.
For one level only one NE2 is sufficient. For use with
a level-monitor for more levels, normally one NE2 per
level is required.
Electrode NE2
SW 27
2000 ±10
14
20
10
rt / RD
rt / RD
1/2"
Ø 4
Maße in mm
43
Part number:
V223429
2014-04-30
146 ZIEHL industrie-elektronik, 74523 Schwäbisch Hall, Germany, +49 791 504-0, info@ziehl.de, www.ziehl.de