5秒后页面跳转
UC1904Q PDF预览

UC1904Q

更新时间: 2024-11-14 20:29:27
品牌 Logo 应用领域
德州仪器 - TI /
页数 文件大小 规格书
6页 306K
描述
UC1904Q

UC1904Q 技术参数

生命周期:ObsoleteReach Compliance Code:unknown
风险等级:5.84Is Samacsys:N
Base Number Matches:1

UC1904Q 数据手册

 浏览型号UC1904Q的Datasheet PDF文件第2页浏览型号UC1904Q的Datasheet PDF文件第3页浏览型号UC1904Q的Datasheet PDF文件第4页浏览型号UC1904Q的Datasheet PDF文件第5页浏览型号UC1904Q的Datasheet PDF文件第6页 
UC1904  
UC2904  
UC3904  
Precision Quad Supply and Line Monitor  
FEATURES  
DESCRIPTION  
Inputs for Monitoring Up to Four  
Supply Voltages  
The UC1904 Quad Supply Monitor will respond to under- and over-volt-  
age conditions on up to four continuously monitored voltage levels. Four  
independent positive voltages can be monitored or, alternatively, two of  
the sense inputs are preset to monitor -5V and -12V supplies. The de-  
vice also monitors Over-Current and Line Sense inputs, both with preci-  
sion input thresholds.  
Two Inputs Preset for -5V and -12V  
Monitoring, or Programmable  
Positive Levels  
Precision 2.5V Reference  
Four open collector outputs on the UC1904 give the following re-  
sponses: 1. The OV/OC output is a latched over-voltage, or over-current  
response. 2. A Power Good signal responds low with any fault detection  
– on power-up a programmable delay is used to hold this output low for  
a system Power On Reset signal. 3. The PWRW output responds only to  
a Line Sense input, for early warning of power failures. 4. The last open  
collector, the ON/OFF output, generates a delayed supply OFF control  
signal in response to an OFF input command, under-voltage condition,  
or line fault detection.  
Separate Inputs for Over-Current and  
Line Fault Sensing  
Adjustable Under- to Over-Voltage  
Fault Windows  
Latched Over-Voltage and  
Over-Current Output  
Power Good and Power Warning  
Outputs  
The OV-UV fault window is adjustable with a programming input. The  
thresholds are centered around the precision 2.5V reference, with a  
scaled hysteresis for precise, glitch free operation. In the positive mode  
of operation, the fault windows at each of the sense inputs can be inde-  
pendently scaled using external resistors and the 2.5V reference output.  
An Auto Restart function couples with the under-voltage and line sens-  
ing circuits to allow controlled power supply start-up and shutdown.  
Auto Restart Function with ON/OFF  
Control, and Programmable Delay  
Programmable Pwr On Reset Delay  
This device will operate over a supply range of 4.75V to 18V. The device  
is available in a DIP, SOIC, or PLCC outline. This device is ESD pro-  
tected on all pins.  
BLOCK DIAGRAM  
Note: Pin Numbers refer to J, N, and DW Packages.  
4/97  

与UC1904Q相关器件

型号 品牌 获取价格 描述 数据表
UC1904QTR ETC

获取价格

Analog IC
UC1907 TI

获取价格

Load Share Controller
UC1907DW TI

获取价格

1-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO16, 0.150 INCH, PLASTIC, SOIC-16
UC1907DWTR TI

获取价格

1-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO16, 0.150 INCH, PLASTIC, SOIC-16
UC1907J TI

获取价格

LOAD SHARE CONTROLLER
UC1907J883B TI

获取价格

LOAD SHARE CONTROLLER
UC1907L TI

获取价格

LOAD SHARE CONTROLLER
UC1907L883B TI

获取价格

LOAD SHARE CONTROLLER
UC1907N TI

获取价格

1-CHANNEL POWER SUPPLY SUPPORT CKT, PDIP16, PLASTIC, DIP-16
UC1907Q TI

获取价格

1-CHANNEL POWER SUPPLY SUPPORT CKT, PQCC20, PLASTIC, LCC-20