UNISONIC TECHNOLOGIES CO., LTD
U74HCT7046
CMOS IC
PHASE LOCKED LOOP WITH VCO &
LOCK DETECTOR
DESCRIPTION
The U74HCT7046 is phase-locked-loop circuit that comprise a linear
voltage-controlled oscillator (VCO), two-phase comparators (PC1, PC2),
a lock detector, a common signal input amplifier and a common
comparator input.
The lock detector capacitor should be connected between pin
15(CLD) and pin 8(GND).For a frequency range of 100kHz to 10MHz,the
lock detector capacitor must be 1000pF to 10pF,respectively.
The signal can be directly coupled to large voltage signals, or with a
series capacitor coupled to small signals. Small voltage signals can be
kept within the linear region of the input amplifiers with a self-bias input
circuit. The U74HCT7046 and a passive low-pass filter form a
second-order loop PLL. With a linear op-amp, the VCO achieves
excellent linearity.
The VCO requires external capacitor and resistor. R1 (between R1
and GND) and capacitor C1 (between C1A and C1B) determine the
frequency range of the VCO. R2 (between R2 and GND) enables the
VCO to have a frequency offset if required.
For the high input impedance of the VCO, the design of low-pass filters is simplified, and the designer has a wide
choice of resistor/capacitor ranges. At pin 10 (DEMOUT), a demodulator output of the VCO input voltage is provided
in order not to load the low-pass filter. In conventional techniques, the DEMOUT voltage is one threshold voltage
lower than the VCO input voltage, but the DEMOUT voltage of U74HCT7046 equals the VCO input voltage. When
DEMOUT is used, a load resistor (RS) should be connected from DEMOUT to GND; but if unused, DEMOUT should be
left open. The VCO output (VCOOUT) can be connected directly or via a frequency-divider to the comparator input
(COMPIN). If the VCO input is held at a constant DC level, the VCO output signal has a duty factor of 50%
(maximum expected deviation 1%). A LOW level at the inhibit input (INH) enables the VCO and demodulator, while
a HIGH level turns both off to minimize standby power consumption.
FEATURES
* Operating Power Supply Voltage Range: Digital Section 4.5 to 5.5 V
VCO Section 4.5 to 5.5 V
* Up to 18 MHz (typ.) Centre Frequency at VCC = 5V
* Excellent VCO Frequency Linearity
* VCO-Inhibit Control For ON/OFF Keying and for Low Standby Power Consumption
* Minimal Frequency Drift
* Zero Voltage Offset due to OP-Amp Buffering
www.unisonic.com.tw
1 of 16
Copyright © 2012 Unisonic Technologies Co., Ltd
QW-R502-851.A