THERMAL CONVERTERS
The content of this specification may change without notification 10/17/07
TVC Series - High Frequency Thermal Voltage Converters
Custom solutions are available
HOW TO ORDER
TVC1 R-100 G X M
Packaging
TCR (ppm/°C)
X = ±25
Resistance Tolerance
G = ±2%
Resistance
50Ω = 500
100Ω = 101
FEATURES
1,000Ω = 102
2,000Ω = 202
Complete thermal converter module using the MJTC thermal
converter as a core device.
Input Connector Type
R = Receptacle Connector
P = Plug Connector
Dedicated high-frequency chassis with input and output
connectors.
Employs the virtual-TEE configuration ("internal" or "built-in")
High Frequency Thermal Voltage Converter
TVC1 = Mounted SMA Connector
TVC2 = No SMA Connector
TEE
Evaluation of frequency characteristic of the ac-dc transfer
difference possible at 10-6 level up to 1MHz.
INTERNAL SCHEMATIC
APPLICATIONS
For high-precision AC-DC transfer standards.
SPECIFICATIONS & PERFORMANCE
Characteristic
Rated Power
TVC1
0.1W
0.5W
TVC2
Max Applied Power
Resistance (Ω)
TCR (ppm/°C)
50, 100, 200, 500, 1K, or 2K
±25
Tolerance
±2%
Frequency Range
Connector Type
DC-10MHz
Receptacle or Plug
More than 60mV
340 Ohms ±30%
±300ppm/K
More than 0.6 V/W
-0.001mV/mW/K (typical)
2.5 ± 0.6 sec (63% response)
< 10ppm (typical)
< 10ppm (typical)
25°C ± 5°C
Rating output voltage
Output Resistance
TC of Output Resistance
Sensitivity
Values of Ri (the ID Resistor)
TC of Sensitivity
Input Resistance, R
ID Sense Resistors, Ri
Response Time
50 Ω
100 Ω
200 Ω
500 Ω
1K Ω
50 – (56) – 82Ω
AC-DC Difference, 10k-100kHz
AC-DC Difference, 100K-1MHz
Operating Temperature
Storage Temperature
100 – (120) – 180Ω
200 – (220) – 470Ω
500 – (560) – 820Ω
1.0K – (1.2K) – 1.8KΩ
2.0K – (2.2K) – 4.7KΩ
-20°C ~ +60°C
2K Ω
Note: The values in ( ) are nominal values.
Note: Output Capacitance. The shunting capacitance between the output pins is 10nF.
DIMENSIONS (mm)
TVC COMPONENTS
Item
Model
Thermal Converter
RF Input SMA
RF Input R / P
DC Output
AAC MJTC
Hirose HRM-301B
Shuner 23N_50-0-23/133NE
Lemo 3pin EHV2B303CLL
AC Input Receptacle
AC Input Plug
Shuner 23N_50-0-23/133NE
Shuner 13N_50-0-33/133NE
Dimensions of TVC1 and TVC2 are the same, except
the SMA connector is not mounted in the TVC2.
188 Technology Drive, Unit H Irvine, CA 92618
TEL: 949-453-9888 FAX: 949-453-8889
1
American Accurate Components, Inc.