TU425
425W Single Output
Test and Measurement/Industrial Series
Features
.
.
.
.
.
.
.
.
.
3.3” x 6.2” x 1.62” Package
Up to 425W of Air-Cooled Power, 300W Convection
Universal Input 90-264Vac Input Range
5V at 2A Isolated Standby Output
Isolated 12V Fan Output
Inhibit, Power Fail, DC OK Signals, Remote Sense
Approved to CSA/EN/IEC/UL60950-1, 2nd Edition
Compliant to high levels of EMC per EN61000-4
Meets Class B Conducted EMI with 6db margin,
Class A Radiated EMI with 3db margin
.
.
Efficiency 90% typical
3 Year Warranty
Description
A Superior performance 425 Watts AC to DC power supply designed for Test and Measurement and Industrial applications. Feature
rich and highly efficient TU425 product family with active current share for redundant applications can easily fit in 1U chassis and
provides 300 Watts for convection or 425 Watts with moving air. Input & output monitoring alarms plus isolated 12V/1A fan output
and 5V/2A standby voltage are among other standard offering of TU425 family. All models are CE marked to low voltage directive
and approved to ITE standards of IEC/UL/EN60950 and CSA C22.2, 2nd edition.
Model Selection
Model
Output Current
Efficiency³
(Main Output)
88%
Ripple & Noise4
(mV pk-pk)
120mV
Total
Regulation
±3%
±5%
±10%
±3%
±5%
±10%
±3%
±5%
±10%
±3%
±5%
±10%
±3%
±5%
OVP
Number
Volts
12V
w/200LFM air¹
Convection²
Threshold
14.0 ± 1.1V
5.5V – 8.0V
N/A
21.0 ± 2.0V
5.5V – 8.0V
N/A
28.0 ± 2.5V
5.5V – 8.0V
N/A
55.0 ± 4.0V
5.5V – 8.0V
N/A
MTBF7
389,750
32.2A
2.0A
1.0A
22.0A
2.0A
0.5A
TU425S12E
TU425S18E
TU425S24E
TU425S48E
TU425S56E
5Vsb
100mV
360mV
12V Fan5
88%
90%
90%
90%
356,330
355,520
354,722
354,560
18V
5Vsb
21.4A
2.0A
1.0A
14.6A
2.0A
0.5A
180mV
100mV
360mV
240mV
100mV
360mV
480mV
100mV
360mV
560mV
100mV
360mV
12V Fan5
24V
5Vsb
16.8A
2.0A
1.0A
11.9A
2.0A
0.5A
12V Fan5
48V
5Vsb
8.4A
2.0A
1.0A
5.9A
2.0A
0.5A
12V Fan5
56V³
5Vsb
7.2A
2.0A
1.0A
5.1A
2.0A
0.5A
63.0 ± 4.0V
5.5V – 8.0V
N/A
12V Fan5
±10%
Notes:
1.
2.
3.
4.
Total power with 200lfm of forced air cooling is 425W (385W for 12V model) including 12V/1A for Fan output and 5V/2A standby.
Maximum convection cooled power is limited to 280W for 12V model and 300W for other models. This includes 12V/0.5A fan output and 5V/2A standby output.
Efficiency values listed are typical and are measured at 115Vac input, full load output current, at an ambient temperature of 25°C.
Measured at 25°C ambient with noise probe directly at end of 6” twisted pair terminated with 0.1μF ceramic and 10μF low ESR capacitors. Values will be higher at ambient
temperatures below 0°C.
5.
Fan Output: If the load on this output is other than a fan, a short circuit condition on this output can only be remedied by removing both the cause of the short circuit and the
load. This will allow the output to resume normal operation.
6.
No output adjustment for 56V model.
7.
MTBF values are in hours, per Telcordia 332, Issue 6, 25°C, full rated load (w/airflow) at 110Vac input.
www.slpower.com
TU425 REV 2.8 29-MAY-15
1