1500W True Sine Wave DC-AC Power Inverter
TS-1500 series
Features :
True sine wave output (THD<3%)
High surge power up to 3000W
High efficiency up to 91%
Power ON-OFF switch
Standby saving mode can be selectable
Front panel indicator for operation status
Thermostatically controlled cooling fan
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp.
/ Output short / Input polarity reverse / Overload
Application : Home appliance, power tools, office and portable
equipment, vehicle and yacht ...etc.
Optional monitoring software
E13
3 years warranty
SPECIFICATION
MODEL
TS-1500-112
TS-1500-124
TS-1500-148
TS-1500-212
TS-1500-224
TS-1500-248
RATED POWER (Typ.)
1500W
MAXIMUM OUTPUT POWER (Typ.) 1725W for 180 sec. / 2250W for 10 sec. / surge power 3000W for 30 cycles
AC VOLTAGE
100 / 110 / 115 / 120VAC selectable by setting button
60 0.1Hz 50/60Hz selectable by setting button S.W
Note.2 True sine wave (THD<3%) at rated input voltage
3.0%
200 / 220 / 230 / 240VAC selectable by setting button
50 0.1%Hz 50/60Hz selectable by setting button S.W
FREQUENCY
OUTPUT
WAVEFORM
AC REGULATION (Typ.)
SAVING MODE (Typ.)
Default disabled. Load 5W will be changed to standby mode
FRONT PANEL INDICATOR
BAT. VOLTAGE
Battery voltage level, output load level, saving mode, fault and operation status
24V
48V
24V
48V
12V
12V
VOLTAGE RANGE (Typ.)Note.1 10.5 ~ 15VDC
21 ~ 30VDC
75A
42 ~ 60VDC
37.5A
10.5 ~ 15VDC
150A
21 ~ 30VDC
75A
42 ~ 60VDC
37.5A
DC CURRENT (Typ.)
Note.5 150A
18W @ standby saving mode
INPUT
NO LOAD DISSIPATION
OFF MODE CURRENT DRAW
1mA
EFFICIENCY (Typ.)
BATTERY TYPES
FUSE
Note.2 87%
89%
89%
88%
90%
91%
Open & sealed Lead Acid
40A*5
30A*3
30A*2
45 4%
42 4%
40A*5
30A*3
30A*2
45 4%
42 4%
BATTERY
INPUT
PROTECTION
11.3 4%
22.5 4%
21 4%
11.3 4%
10.5 4%
22.5 4%
21 4%
BAT. LOW ALARM
BAT. LOW SHUTDOWN
REVERSE POLARITY
10.5 4%
By internal fuse open
82
5
82
5
96
5
68
5
68
5
68
5
OVER TEMPERATURE
OUTPUT SHORT
Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH3 detect on heatsink of power transistor
Protection type : Shut down o/p voltage, re-power on to recover
OUTPUT
PROTECTION
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
OVER LOAD (Typ.)
Protection type : Shut down o/p voltage, re-power on to recover
GFCI PROCTECTION
WORKING TEMP.
UL458 (only for "GFCI" receptacle-Type F )
0 ~ +40 @ 100% load ; 60 @ 50% load
20% ~ 90% RH non-condensing
None
Note.3
WORKING HUMIDITY
ENVIRONMENT
-30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH
STORAGE TEMP., HUMIDITY
VIBRATION
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
None
SAFETY STANDARDS
LVD
UL458 (only for "GFCI" receptacle-Type F )
EN60950-1
None
SAFETY &
EMC
Bat I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC
WITHSTAND VOLTAGE
EMC EMISSION
Compliance to EN55022 class B, 72/ 245/ CEE, 95/ 54/ CE, E-Mark
Compliance to EN61000-4-2,3,8
Compliance to FCC class A
None
EMC IMMUNITY
CONTROL WIRING
DIMENSION
RJ11 -RS232 (Option)
OTHERS
NOTE
420*220*88mm (L*W*H)
6.81Kg; 2pcs/14.6Kg/1.61CUFT
PACKING
1.Output derating capacity referenced by curve 1.
2.THD and Efficiency is tested by 1000W, linear load at 13V, 26V, 52V input voltage.
3.Output derating capacity referenced by curve 2.
4.All parameters not specified above are measured at rated load, 25 of ambient temperature.
5.DC current is tested by 1500W, linear load at 13V, 26V, 52V input voltage.
File Name:TS-1500-SPEC 2012-02-21