Total Power International, Inc.
40W Desk Top Type
I.T.E. Power Supplies
TPSPU41A SERIES
Features:
Wide Operating Voltage 90 to 264 VAC,47 to 63 Hz
IEC-320-C14 Input Inlet
Optional Output Connector (See page appendix)
Single Output
Class I
Energy Star 2.0, Efficiency level V
2 year warranty
Electrical Characteristics:
Safety Approvals Input Voltage Range
100~240VAC
90~264VAC
47~63Hz
Vin
Application:
Operate Voltage Range
- POS System
- AV Equipment
- Industrial PC
- Note PC
Input Frequency
fin
Output Power Range
Output Voltage Range
Output Current Range
Input Current (Low Line)
Input Current (High Line)
See rating chart
See rating chart
See rating chart
Po
Vo
Io
- Charger
- LED Lighting
Io=Full load, Vin=100VAC
Io=Full load, Vin=240VAC
Io=Full load, 25°C, Cool start, Vin=115VAC
Io=Full load, 25°C, Cool start, Vin=230VAC
Io=Full Load, Vin=230VAC
Io=Full Load
Iil
0.93A
0.93A
Iih
45A (max.)
90A (max.)
Low Line Inrush Current
High Line Inrush Current
Efficiency
Ir
Safety Approvals:
83~90%
Eff
Line Regulation
0.5~1%
REG-i
REG-o
Load Regulation
Vin=230VAC
4~5%
Over Current Protection
110~150%
4mS (max.)
10mS (min.)
2S (max.)
2% (max.)
0.75mA (max.)
OCP Over Current Protection
RoHS
2002/95/EC
COMPLIANT
Time of Transient Response
Hold-Up Time
Io=Full Load to Half Load, Vin=100VAC
Io=Full Load, Vin=110VAC
Io=Full Load, Vin=100VAC
Full Load, Vin=90VAC
Ttr
Th
Ts
UL/c-UL(UL 60950-1:2nd Edition)
TUV/GS(EN 60950-1:2nd Edition)
Start Up Time
Vp-p Ripple & Noise(Peak to Peak)
Safety Ground Leakage Current
Ilk
Vin=240VAC/60Hz
All output
Temperature Coefficient
TC
0.04%/°C
See rating chart
No-Load Power Consumption
No load, Vin=230VAC
Pno
Vps
Dielectric Withstanding Voltage
for Primary to secondary
Primary to secondary
4242VDC (min.)
2550VDC (min.)
Dielectric Withstanding Voltage
for Primary to PE
Vpg
Ris
Primary to PE
Test Voltage=500VDC
(min.)
50M
Isolation Resistance
Environmental
Operating Temperature
To
Ts
See derating curve
-40~85°C
Storage Temperature
Operating Humidity
Storage Humidity
0~95%
Ho
0~95%
Hr
Operating Temperature at 25°C,Calculated per MIL-HDBK-217F
0.1M Hrs (min.)
MTBF
Pd
Derate linearly from 100% load at 40°C to 50% load at 70°C
Total Power International, Inc
Toll Free: 877-646-0900
www.total-power.com