TPC/GKF-320-XS series
300-312W Wide input AC/DC switching power supply
DESCRIPTION
:
The rated output power of TPC/GKF-320-XS series is 300~312W input voltage range 90-264VAC,
,
:
output voltage : 12V,24V. High reliability, precision,effificency , ultra-small size, no external heat sink
required, stable output voltage and etc, with short circuit, over-load,over-Power protection,
Widely used in telecommunications, industrial control, instrument, data acquisition,
signal control , New Energy, Security,DC motor,CNC system and other electronic systems.
FEATURES
AC input 90-264 VAC
Built-in cooling fan speed control
short circuit, over-load protection
Operating temperature
:-20℃~65℃
Withstand 300Vac surge input for 5 sec
Built-in active PFC,PF>0.95
RoHS complaint
Altitude up to 5000m
High efficiency, long life and high reliability
SELECTION GUIDE
Input
Volatge VAC)
Output
Efficiency
(
Part Number
@25℃,
Rated
Pre-set voltage
@25 (V)
Rated current
Current
range(A)
Voltage
(VDC)
(Typ)
%
(A
)
℃
power(W)
Rated
Range
300
312
TPC/GKF-320-12S
TPC/GKF-320-24S
220
220
90-264
90-264
12
24
12.00-12.10
24.00-24.10
25
13
0-25
0-13
≥84.5
≥87
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
OUTPUT CHARACTERISTICS
Conditions
Conditions
Parameter
Ripple and noise,Ta is ambient 0
<
Ta
≤
65
℃
12V output voltage
24V output voltage
12V output voltage
24V output voltage
12V output voltage
24V output voltage
≤
≤
200mVp-p
150mVp-p
Ripple and noise,Ta is ambient -20
<
Ta
≤0℃
2.5A-25A
1.3A-13A
10V~15V
20V-27V
:
:
<
±
600mV
2.5A-12.5A
1.3A-6.5A
:
<
±
300mV
12.5A-25A
:<±300mV
Dynamic load characterstics, -20
<
Ta≤65℃
<1200mV
:
<600mV
6.5A-13A <600mV
:
Output adjustment range @25
℃
Voltage regulation accuracy@-20~65
Line regulation@-20~65
Load regulation@-20~65
Temp. coefficient@-20~65
℃
±
±
±
±
≤
≤
≥
2%@12V(11.76-12.24) /
±
±
1%@24V(23.76-24.24)
℃
0.5%
℃
2%@12V(11.76-12.24) /
1%@24V(23.76-24.24)
℃
0.03%/℃
2.0S ( 230Vac input, full load
4.0S (120Vac input, full load
)
Set-up time@25
℃
)
Hold-up time@25
℃
10mS( 230Vac/115Vac input, full load )
Overshoot&Undershoot@-20~65
℃
<5.0%
INPUT CHARACTERISTICS
Conditions
Parameter
Input voltage range
MAX input voltage
Rated input voltage range
Frequency Range
90Vac~264Vac 120~370VDC
300Vac 10S
100Vac~240Vac
47Hz~63Hz
Power factors@25
Set-up voltage@-20~65
Input current@25
Inrush current @25
℃
PF>0.98/120VAC
&
PF>0.95/230VAC (at full load)
℃
90Vac 70% load set-up,@-20℃)(100% load set-up, 230VAC INPUT @-40℃)
(
℃
≤
≤
4.5A
50A@220Vac Cold start
℃
≤30A@110Vac Cold start
www.gztoppower.com
TEL:0086-20-62162688
Email:sales2@gztoppower.com