7W 4KVAC Isolation Wide Input AC/DC Converters
DESCRIPTION
:
The rated output power of TP07AC series is7W with wide input voltage range, for both AC input
and DC input application. High reliability, precision, large power density, ultra-small size, no
external heat sink required, stable output voltage and etc, with over current protection, EMI filter
circuit, the rectifier filter circuit, 4000V isolation voltage, short circuit, overload, internal thermal
protection, Widely used in telecommunications, industrial control, instrument, data acquisition,
signal control and other electronic systems.
FEATURES
Universal input voltage range
Fixed switching frequency
Short circuit protection
Both for AC and DC input voltage
Overheat protection
Wide input voltage: 4:1
Over current protection
Operating temperature :-25
RoHS compliant
℃ to 70℃
Input Voltage
Rated
Output
Efficiency (Typ. )
%
Part Number
Voltage
(
VDC)
Current(A)
(VAC)
85-265
85-265
85-265
85-265
85-265
85-265
(VDC)
110-370
110-370
110-370
110-370
110-370
110-370
1.4
TP07AC220S05W
TP07AC220S06W
TP07AC220S09W
TP07AC220S12W
TP07AC220S15W
TP07AC220S24W
5
69
69
73
75
76
78
1.16
0.77
0.58
0.46
0.29
6
9
12
15
24
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
GENERAL CHARACTERISTICS
Parameter
Conditions
Min.
47
Typ.
Max.
63
Units
Isolation voltage
Input Frequency
Over current protection
Cooling
Input / Output 1 minute, leakage current 2mA
4000
VAC
HZ
10~55Hz
Full input range
Auto recovery
Free air convection
Case material
Flame-retardant plastic
INPUT CHARACTERISTICS
Parameter
Conditions
Min.
85
Typ.
Max.
300
Units
VAC In module(85V-300V)
Startup voltage
220
220
VAC
Startup voltage
110
375
VDC
VDC In module(110V-370V)
External fuse recommended value(wiring, rail type Package has included fuse)
Fuse must be connected, recommended 1A / 250V slow-off type
OUTPUT CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
Max.
±2
Units
Voltage accuracy
Line regulation
Load regulation
%
%
Full load
±0.5
±1
10%~100% load
%
W
Standby power consumption
0.3
Over current protection
Over voltage protection
Ripple and noise
≥110%Io, self-recovery
Over-voltage shutdown output
20MHz bandwidth
50
100
mv
Short-circuit protection
Switch frequency
Hiccup-type, sustainable short-circuit, self-recovery
140
12
110VAC
230VAC
ms
Power-down hold time
80
ms
www.gztoppower.con
TEL:0086-20-82019000
Email:sales2@gztoppower.com