TP03(05)AD Series
3W, 5W 3KVAC Isolation Wide Input AC/DC Converters
DESCRIPTION
:
TP03(05)AD series is 3W ,5W with wide input voltage range, for both AC input and DC input application, come
with Low power consumption <0.05W , low Leakage current @0.1mA ,miniature size:35*25.4*18mm ,and
good EMC performance, can meet the EMC and safety specifications: IEC / EN61000-4 CISPR32 / EN55032,
UL62368, EN62368, IEC62368 and other related standards. This series of power supplies have important
applications in many fields such as LED, street light control, industry, office and civil industries ,etc.***please
refer to the application circuit when the parts is applied in the environment with severe electromagnetic
compatibility.
FEATURES
Universal input voltage range
Low Ripple &Noise
Wide input voltage: 4:1
Low power consumption <0.05W
High efficiency, high power density, miniature
RoHS compliant
Over load/short circuit protection
Operating temperature: -40
℃ to 70℃
Both for AC and DC input voltage
SELECTION GUIDE
Efficiency (Typ. )
Input
Output
Part Number
%
Voltage VAC
85-305
85-305
85-305
85-305
85-305
85-305
85-305
85-305
85-305
85-305
85-305
85-305
Voltage VDC
120-430
120-430
120-430
120-430
120-430
120-430
120-430
120-430
120-430
120-430
120-430
120-430
Voltage
(VDC)
Current
(A)
66
76
78
79
80
81
68
78
79
80
81
81
TP03AD220S03W
TP03AD220S05W
TP03AD220S09W
TP03AD220S12W
TP03AD220S15W
TP03AD220S24W
TP05AD220S03W
TP05AD220S05W
TP05AD220S09W
TP05AD220S12W
TP05AD220S15W
TP05AD220S24W
3.3
0.70
5
9
0.60
0.33
0.25
0.20
0.12
1.00
1.00
0.56
0.42
0.33
0.21
12
15
24
3.3
5
9
12
15
24
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
INPUT SPECIFICATIONS
Conditions
DC input
AC input
Parameter
Min.
120
Typ.
220
Max.
Units
VDC
430
305
440
Input Voltage Range
85
47
220
VAC
HZ
mA
mA
A
Input Voltage Range
Input Frequency
Input Current
115VAC
230VAC
115VAC
230VAC
95
46
Input Current
Inrush Current
Inrush Current
Recommended External Fuse
Hot Plug
10
30
A
Fusible resistor
:
10Ω/1W
Unavailable
Leakage current
<0.1mA at 265VAC/50Hz
OUTPUT SPECIFICATIONS
Conditions
Parameter
Min.
Typ.
Max.
±2
Units
%
Output Voltage Accuracy
±3
%
Output Voltage Accuracy(3.3Voutput)
Line Regulation
±1
%
Load Regulation
±1
%
Short Circuit Protection
Temperature Coefficient
Start rising time
over-voltage/over-current/short circuit protection, self-recovery
0~50
℃
±0.03
200
100
15
%/
℃
115VAC input
230VAC input
115VAC input
230VAC input
ms
Start rising time
ms
ms
Output hold time
Output hold time
40
ms
www.gztoppower.com
TEL:0086-20-62162688
Email:sales2@gztoppower.com
Page 1 / 3