■
■
RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany
■
■
■
RSG
■
Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de www.rsg-electronic.de
ELECTRONIC COMPONENTS
Änderungen vorbehalten / subject to change without notice
100W Triple Output with PFC Function
TP-100 series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.94
Protections:Short circuit/Over load/Over voltage
Free air cooling convection
Fixed switching frequency at 100KHz
3 years warranty
..
SPECIFICATION
MODEL
TP-100A
TP-100B
TP-100C
TP-100D
OUTPUT NUMBER
DC VOLTAGE
CH1
5V
CH2
12V
4A
CH3
-5V
CH1
5V
CH2
12V
4A
CH3
-12V
0.6A
CH1
5V
CH2
15V
3A
CH3
-15V
0.6A
CH1
5V
CH2
24V
2A
CH3
12V
0.6A
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
10A
0.6A
10A
10A
10A
3 ~ 15A 0.4 ~ 5A 0 ~ 1A
101W
3 ~ 15A 0.4 ~ 5A 0 ~ 1A
105.2W
3 ~ 15A 0.4 ~ 4A 0 ~ 1A
104W
3 ~ 15A 0.4 ~ 3A 0 ~ 1A
105.2W
RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 100mVp-p 100mVp-p 120mVp-p 100mVp-p 100mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 100mVp-p
VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 3.0%
OUTPUT
7.0%
1.0%
6.0%
6.0%
1.0%
4.0%
3.0%
1.0%
3.0%
6.0%
1.0%
6.0%
6.0%
1.0%
4.0%
3.0%
1.0%
3.0%
+10,-6% 6.0%
3.0%
1.0%
3.0%
8.0%
1.0%
6.0%
6.0%
1.0%
4.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD TIME (Typ.)
1.0%
3.0%
1.0%
6.0%
1.0%
4.0%
800ms, 60ms/230VAC
800ms, 60ms/115VAC at full load
24ms/230VAC
Note.5 90 ~ 264VAC
47 ~ 63Hz
24ms/115VAC at full load
127 ~ 370VDC
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
PF>0.94/230VAC
75%
PF>0.98/115VAC at full load
78%
77%
78%
INPUT
1.5A/115VAC
0.75A/230VAC
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
COLD START 40A/230V
<3.5mA / 240VAC
105 ~ 150% rated output power
OVER LOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1:5.75 ~ 6.75V on +5V
PROTECTION
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
95
5
(TSW1)
OVER TEMPERATURE(OPTION)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
0.03%/ (0~50
)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 1min.
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
SAFETY &
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
EMC
(Note 4)
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
170.1K hrs min. MIL-HDBK-217F (25
199*99*50mm (L*W*H)
)
DIMENSION
PACKING
OTHERS
NOTE
0.83Kg; 20pcs/17.6Kg/1.28CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:TP-100-SPEC 2006-08-22