TN
SLIM POLARIZED RELAY
FEATURES
TN RELAYS
5.6
.220
14
.551
• Small header area makes higher
density mounting possible
• High sensitivity: 140 mW nominal
operating power (single side stable
3-12 V type)
• Surge voltage withstand: 1500 V FCC
Part 68
• Self-clinching terminal also available
9.8
.386
mm inch
RoHS Directive compatibility information
http://www.nais-e.com/
SPECIFICATIONS
Contact
Characteristics
Arrangement
2 Form C
60 mΩ
Initial insulation resistance*1
Min. 1,000 MΩ (at 500 V DC)
750 Vrms for 1 min.
(Detection current: 10 mA)
Initial contact resistance, max.
(By voltage drop 6 V DC 1A)
Between open
contacts
Initial
breakdown
voltage
Contact material
Gold-clad silver
Between contact and
coil
1,000 Vrms for 1 min.
(Detection current: 10 mA)
Nominal switching capacity
(resistive load)
1 A 30 V DC,
0.5 A 125 V AC
1,000 Vrms for 1 min.
(Detection current: 10 mA)
Between contact sets
Max. switching power
(resistive load)
30 W, 62.5 VA
FCC surge voltage between open
contacts
Temperature rise*2 (at 20°C)
Operate time [Set time]*3 (at 20°C)
Release time [Reset time]*4
1,500 V
Rating
Max. switching voltage
110 V DC,125 V AC
1 A
Max. 50°C
Max. 3 ms [Max. 3 ms]
Max. switching current
Min. switching capacity
(Reference value)#1
10 µA 10 mV DC
Max. 3 ms [Max. 3 ms]
(at 20°C)
140 mW (3 to 12 V DC)
200 mW (24 V DC)
300 mW (48 V DC)
Single side stable
Nominal
Functional*5
Destructive*6
Min. 490 m/s2 {50G}
Min. 980 m/s2 {100G}
Shock resistance
operating
1 coil latching
power
100 mW (3 to 12 V DC)
150 mW (24 V DC)
176.4 m/s2 {18G}, 10 to 55 Hz
at double amplitude of 3 mm
294 m/s2 {30G}, 10 to 55 Hz
at double amplitude of 5 mm
Functional*7
Vibration resistance
200 mW (3 to 12 V DC)
300 mW (24 V DC)
2 coil latching
Destructive
Mechanical (at 180 cpm)
108
Conditions for
Ambient
–40°C to +70°C
–40°F to +158°F
Expected
life (min.
operations)
1 A 30 V DC
resistive load
operation, transport temperature
2 × 105
and storage*8
Electrical
(at 20 cpm)
(Not freezing and
condensing at low
0.5 A 125V AC
resistive load
105
Humidity
5 to 85% R.H.
temperature)
Note:
Unit weight
Approx. 1.5 g .053 oz
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load. (SX relays are available for low level load switching [10V DC, 10mA
max. level])
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage" section.
*2 By resistive method, nominal voltage applied to the coil; contact carrying current:
1 A.
*5 Half-wave pulse of sine wave: 11 ms; detection time: 10 µs.
*6 Half-wave pulse of sine wave: 6 ms.
*7 Detection time: 10 µs.
*8 Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT .
*3 Nominal voltage applied to the coil, excluding contact bounce time.
*4 Nominal voltage applied to the coil, excluding contact bounce time without diode.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.