TRUMPower
150 WATT MEDICAL POWER ADAPTERS
DESCRIPTION
TMP150 SERIES
Class I, Class II
(LVD)
The TMP150 is a series of medical grade, class I
and class II, AC/DC desktop power adapters of 132
to 150 watts output power. They are enclosed in a
94V-1 rated case with an IEC 320/C14 or IEC
320/C18 AC inlet to mate with interchangeable cord
for world-wide use. All models meet CISPR 11 and
FCC class B emission limits, and are designed for
medical applications.
RoHS
FEATURES
‧ Low safety ground leakage current
‧ Optional output connectors
‧ 100% burn-in
‧ 90 to 264VAC wide input range
‧ Overvoltage & overcurrent protections
‧ 0.98 PFC
‧ Compliant with CEC and Energy Star efficiency
level IV requirements
Safety Standard Approvals:
‧ No load consumption less than 0.5W
‧ Average active efficiency≧ 85%
‧ Compliant with RoHS requirements
UL 60601-1
CSA C22.2 No. 601.1
TÜV EN60601-1
INPUT SPECIFICATIONS
Input voltage:
GENERAL SPECIFICATIONS
90 to 264VAC
47 to 63Hz
Switching frequency: 30KHz ~ 110KHz
Input frequency:
Input current:
2.0A (rms) for 115VAC
1.0A (rms) for 230VAC
90µA max. @ 115VAC, 60Hz
150µA max. @ 230VAC, 50Hz
Power factor:
Efficiency:
0.98 typical at 115VAC
85% min.
Earth leakage current:
(Class I)
Enclosure leakage current:
(Class II)
Hold-up time:
Line regulation:
15 msec minimum at 110VAC
±0.5% maximum at full load
90µA max. @ 264VAC, 50Hz
Inrush current:
60 amps @ 115VAC or 100 amps
@ 230VAC, at 25ºC cold start
4000VAC from input to output
1500VAC from input to ground
500VAC from output to ground
150,000 hours minimum at full load
At 25ºC ambient, calculated per
MIL-HDBK-217F
Withstand voltage:
OUTPUT SPECIFICATIONS
Output voltage/current:
Total output power:
Ripple and noise:
See rating chart
See rating chart
MTBF:
2% peak to peak maximum
Set at 112 – 140% of its nominal
output voltage
Overvoltage protection:
EMC Performance
EN55011:
FCC:
Class B conducted, Class B radiated
Class B conducted, Class B radiated
Class B conducted, Class B radiated
Harmonic distortion, Class D
Line flicker
Overcurrent protection:
All outputs protected to short
circuit conditions
VCCI:
Temperature coefficient:
Transient response:
All outputs ±0.04%/ºC maximum
EN61000-3-2:
EN61000-3-3:
EN61000-4-2:
Maximum excursion of 4% or
better on all models, recovering
to 1% of final value within 500µs
after a 25% step load change
ESD, ±8KV air and ±6KV contact
EN61000-4-3:
EN61000-4-4:
EN61000-4-5:
EN61000-4-6:
EN61000-4-8:
EN61000-4-11:
Radiated immunity, 3V/m
Fast transient/burst, ±2KV
Surge, ±1KV diff, ±2KV com.
Conducted immunity, 3Vrms
Magnetic field immunity, 3A/m
ENVIRONMENTAL SPECIFICATIONS
Operating temperature: 0ºC to +60ºC
Voltage dips, 30% reduction for
500ms, 60% reduction for 100ms
and >95% reduction for 10ms
Storage temperature:
Relative humidity:
Derating:
-40ºC to +85ºC
5% to 95% non-condensing
Derate from 100% at +40ºC linearly
to 50% at +60ºC
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: sales@trumpower.com ● Website: www.TRUMPower.com