APPLICABLE STANDARD
OPERATING
STORAGE
TEMPERATURE RANGE
-55 C TO +85 C
2 -25 C TO +60 C
1
TEMPERATURE RANGE
RATING
VOLTAGE
CURRENT
125 V AC
500 mA
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
X
X
X
X
MARKING
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE
100 mA MAX (DC OR 1000 Hz AC).
230 m MAX.
X
X
(AN EXAMPLE OF CONNECTOR CONFIGURATION
IS SHOW N.)
100 V DC.
INSULATION RESISTANCE
VOLTAGE PROOF
100 M MIN.
X
X
X
X
500 V AC FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
MECHANICAL OPERATION
200 TIMES INSERTIONS AND EXTRACTIONS.
1) CONTACT RESISTANCE: 250 m MAX.
2) NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
-
-
-
X
X
X
VIBRATION
FREQUENCY 10 TO 55 Hz
1) NO ELECTRICAL DISCONTINUITY OF 5 s.
2) CONTACT RESISTANCE: 250 m MAX.
3) NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
SINGLE AMPLITUDE 0.75 mm,
AT 2 h FOR 3 DIRECTIONS.
SHOCK
490 m/s2 DURATION OF PULSE 11 ms
AT 3 TIMES FOR 3 DIRECTIONS.
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT,CYCLIC
EXPOSED AT +40 C, 90 TO 95 , 500 h
1) CONTACT RESISTANCE: 250 m MAX.
2) INSULATION RESISTANCE:
1 M MIN. (AT HIGH HUMIDITY)
10 M MIN. (AT DRY)
3) NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
-
-
X
RAPID CHANGE OF
TEMPERATURE
TEMPERATURE -55±3→5 TO 35→85±2→5 TO 35℃
1) CONTACT RESISTANCE:
250 m MAX.
X
TIME
30 TO 35→5 MAX→30 TO 35→5 MAX min
2) INSULATION RESISTANCE: 100 M MIN.
3) NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
UNDER 5 CYCLES.
CORROSION SALT MIST
EXPOSED IN 5 % SALT WATER SPRAY FOR
48 h.
1) CONTACT RESISTANCE:
2) NO HEAVY CORROSION.
250 m MAX.
-
-
-
X
X
X
RESISTANCE TO
SOLDERING HEAT
SOLDERABILITY
SOLDER TEMPERATURE, 260 ± 5 ℃ FOR
IMMERSION, DURATION 10 ± 1 S.
SOLDERED AT SOLDER TEMPERATURE, 245 ± 2 ℃
FOR IMMERSION, DURATION 3 ± 1 S.
NO DEFORMATION OF CASE AND EXCESSIVE
LOOSENESS OF THE TERMINALS.
MIN. 95 % OF SOLDER IMMERSED AREA
SHALL BE COVERED NEW SOLDER COATING.
① THE PRODUCT PERFORMANCE IS GUARANTEED ONLY IN THE
1
2
TEMPERATURE ADEQUATE TO PEOPLE’S ACTIVITIES.
② THE OPERATION TEMPERATURE INCLUDES THE
RISE BY CURRENT CARRYING.
PACKING MATERIAL IS NOT INCLUDED.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
MN.KENJO
TU.TANIGUCHI
HY.MATSUDA
20201120
20201120
20201120
20201120
Unless otherwise specified, refer to IEC 60512.
DS.HIROWATARI
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-048578-40-00
TM5RL-3232(40)
PART NO.
CODE NO.
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/1
CL0222-2671-0-40
FORM HD0011-2-1