COUNT
COUNT
CHKD
DESCRIPTION OF REVISIONS
CHKD DATE
18.10.24
DESCRIPTION OF REVISIONS
DATE
BY
BY
RE-5-2033
8
Y.K.G
C.D.H
△
△
1
△
APPLICABLE STANDARD
OPERATING TEMPERATURE RANGE
STORAGE TEMPERATURE RANGE
-10℃ ~ +50℃(Packed Condition)
-40℃
~ +105℃ (note1)
1
1
OPERATING OR STORAGE
HUMIDITY RANGE
RELATIVE HUMIDITY 90% MAX (NOT DEWED)
VOLTAGE
CURRENT
RATING
50V [AC(rms) / DC]
FPC/FFC (TYPE A : t=0.3±0.03mm)
(TYPE B : t=0.3±0.05mm)
0.5A [AC(rms) / DC] (note2)
APPLICABLE CABLE
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
VISUALLY AND BY MEASURING INSTRUMENT
CONFIRMED VISUALLY
O
O
O
O
ACCORDING TO DRAWING
MARKING
ELECTRICAL CHARACTERISTICS
CONTACT RESISTANCE
INSULATION RESISTANCE
VOLTAGE PROOF
MATE APPLICABLE FPC/FFC AND APPLY A CURRENT OF
50 mΩ MAX.
O
O
O
O
O
O
AC 20mV MAX, 1mA
INCLUDING FPC/FFC BULK RESISTANCE(L=8mm)
500 MΩ MIN.
MATE APPLICABLE FPC/FFC AND APPLY A VOLTAGE OF
DC 100V
MATE APPLICABLE FPC/FFC AND APPLY A VOLTAGE OF
AC 150V FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
MEASURE BY APPLICABLE FPC/FFC(t=0.3)
①HORIZONTAL DIRECTION : 0.4N*n min.
②VERTICAL DIRECTION : 0.3N*n min.
FPC RETENSION FORCE
1
AT INITIAL CONDITION
O
-
(n = Number of Contacts)(note 3)
MECHANICAL OPERATION
VIBRATION
20 TIMES INSERTIONS AND EXTRATIONS
①CONTACT RESISTANCE: 50mΩ MAX
O
O
O
-
-
-
②NO DAMAGE,CRACK AND LOOSENESS OF PARTS
①NO ELECTRICAL DISCONTINUITY OF 1㎲.
②CONTACT RESISTANCE : 50mΩ MAX
FREQUENCY 10 ~ 55 Hz, TOTAL AMPLITUDE 1.5 mm
AT 2h, IN 3 DIRECTIONS
981m/s2 DIRECTION OF PULSE 6ms AT 3 TIMES
SHOCK
③NO DAMAGE,CRACK AND LOOSENESS OF PARTS
IN 3 DIRECTIONS.
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT(STEADY STATE)
EXPOSED AT 40±2℃, 90~95 %, 96Hr.
①CONTACT RESISTANCE: 50 mΩ MAX.
O
O
-
-
RAPID CHANGE OF TEMPERATURE
TEMPERATURE:-40±2→15~35→+105±2→15~35 ℃
②INSULATION RESISTANCE: 50MΩ MIN.
③NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
1
TIME :
30 → 2~3 →
30 → 2~3 min.
UNDER 5 CYCLES.
DAMP HEAT, CYCLE
TEMPERATURE -10→+65
HUMIDITY : 90~95%
O
-
10 CYCLE(240Hr)
DRY HEAT
EXPOSED AT 105±2℃, 96Hr
EXPOSED AT -40±2℃, 96Hr
①CONTACT RESISTANCE : 50mΩ MAX
②NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
①CONTACT RESISTANCE 50mΩ MAX
O
O
-
-
1
COLD
EXPOSED AT 35±2℃, 5±1% SALT WATER SPRAY FOR 48Hr
O
O
-
-
②NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
③NO EVIDENCE OF CORROSION WHICH AFFECTS
TO OPERATION OF CONNECTOR.
HYDROGEN SULPHIDE
EXPOSED IN 3 PPM FOR 96Hr.
(TEST STANDARD : JEIDA-38)
RESISTANCE TO
1)REFLOW SOLDERING:
①NO DEFORMATION OF CASE OF EXCESSIVE
LOOSENESS OF THE TERMINALS.
SOLDERING HEAT
PEAK TMP. : 250℃ MAX. TMP. 230℃ MIN FOR 60s
2)SOLDERING IRONS TMP. : 350±10℃ FOR 5±1s
SOLDER DIPPING TEMPERATURE 245±5℃
(TEST STANDARD : MIL-STD-202)
O
O
-
②NO DAMAGE OF ELECTRICAL PERFORMANCE
A NEW UNIFORM COATING OF SOLDER
SHALL COVER A MINIMUM OF 95% OF
THE SURFACE BEING IMMERSED.
SOLDER ABILITY
FOR IMMERSION DURATION, 3±0.3 sec.
(note 1)
1
FOLLOW THE SPECIFICATIONS OF FPC/FFC IF IT’S ALLOWABLE MAXIMUM OPERATING TEMPERATURE
IS BELOW 105℃
(note 2)
1
1
WHEN THE SAME VALUE OF CURRENT ARE APPLIED TO ALL CONTACTS AT THE SAME TIME IN ONCE,
SET THE CURRENT TO THE 70% OF THE RATED CURRENT VALUE.
(note 3)
THERE’S A CASE WHICH FPC/FFC RETENTION FORCE DOESN’T FULFILL THE VALUE,
BECAUSE FPC/FFC SPECIFICATION AFFECTS THE RESULT OF FPC/FFC RETENTION FORCE.
RELEASED
ENG
DRAWN
DESIGNED
CHECKED
APPROVED
REMARKS CONDITIONS FOR TESTING
S.G.LEE
S.G.LEE
D.H CHO H.C SONG
18.10.24
DEPT
17.06.02
17.06.02
17.06.02 17.06.02
UNLESS OTHERWISE SPECIFIED, REFER TO JIS C 5402.
NOTE QT: QUALIFICATION TEST AT: ASSURANCE TEST O: APPLICABLE TEST
PART NO.
HIROSE KOREA CO.,LTD.
SPECIFICATION SHEET
TF31-**S-0.5SH (895)
CL 6535-0064-8-895
F-1-021(Rev.0)
CODE NO.(OLD)
DRAWING NO.
CODE NO.
1
1
ELC4-632347
CL