TB65
65W Single Output
Test and Measurement/Industrial Series
Features
.
.
.
2.0 x 3.5” x 1.3” Package
Up to 65W Convection Cooled Output Power
Compliant to high levels of EMC per EN61000-4
.
.
15kV ESD (Air), 8kV (Contact)
4kV Surge
.
Meets Class B Conducted EMI with 6db margin,
Class B Radiated EMI with 3db margin
.
.
.
.
.
.
Up to 90% Efficiency
>10 year e-cap life
Universal Input 90-264Vac Input Range
DC OK Signal, PSU Temperature Signal
Class I and II Input Models
3 Year Warranty
Description
A Superior performance 65 Watts AC to DC power supply designed for Test and Measurement and Industrial applications. Feature
rich and highly efficient TB65 product family can easily fit in 1U chassis and provides 65 Watts, convection cooled. Input, output and
internal temperature monitoring/alarms are additional features of the TB65 family. All models are CE marked to low voltage
directive and approved to ITE standards of IEC/UL/EN60950 and CSA C22.2, 2nd edition.
Model Selection
Model
Output
Output
Current
Ripple & Noise2
(pk-pk)
Total
Regulation
OVP
Threshold
Number4
Voltage (Nom)
Efficiency1
MTBF3
TB65S12K
TB65S15K
TB65S24K
TB65S36K
TB65S48K
12V
15V
24V
36V
48V
5.4A
4.3A
2.7A
1.8A
1.35A
88%
120mV
180mV
240mV
360mV
480mV
±3%
±3%
±3%
±3%
±3%
14.0 ± 1.1V
21.0 ± 2.0V
28.0 ± 2.5V
46.3 ± 3.0V
55.0 ± 4.0V
500,000
88%
90%
88%
90%
500,000
500,000
500,000
500,000
Notes:
1.
2.
Efficiency values listed are typical and are measured at 115Vac input, full load output current, at an ambient temperature of 25°C.
Measured at 25°C ambient with noise probe directly at end of 6” twisted pair terminated with 0.1μF ceramic and 10μF low ESR capacitors. Values will be higher at ambient
temperatures below 0°C.
3.
4.
MTBF values are in hours, per Telcordia 332, Issue 6, 25°C, full rated load (w/airflow) at 110Vac input.
Change the “K” suffix to “C” for Input Class II (ungrounded) models.
General Specifications
85-264Vac, single phase.
(Safety Approved to 90-264Vac).
<2 Seconds at 110Vac.
AC Input
Turn On Time
Rise Time
1.5A at 110Vac, 1A at 240Vac
<30mS, 56V model: <35mS
Input Current
40Arms Maximum within a half line cycle, cold
start at 25C. See application note.
20mS min. from loss of AC input at 110 Vac, full load,
25°C.
Inrush Current
I²T Characteristic
Hold-up Time
Over Load
Protection (OCP)
115% - 200% of rated output current value. Hiccup
Mode, Auto-recovery
See Table below.
www.slpower.com
TB65 REV 2.3 26-SEP-16
1