Technische Information / Technical Information
Schneller Thyristor
F
Fast Thyristor
T 599 F 12...13
Elektrische Eigenschaften / Electrical properties
Höchstzulässige Werte / Maximum rated values
Tvj = - 40°C...Tvj max
Tvj = - 40°C...Tvj max
Tvj = + 25°C...Tvj max
Periodische Vorwärts- und Rückwärts-Spitzensperrspannung
repetitive peak forward off-state and reverse voltages
VDRM , VRRM
1200
1300
V
V
Vorwärts-Stoßspitzensperrspannung
VDSM
1200
1300
V
V
non-repetitive peak foward off-state voltage
Rückwärts-Stoßspitzensperrspannung
non-repetitive peak reverse voltage
VRSM
1300
1400
V
V
Durchlaßstrom-Grenzeffektivwert
RMSM on-state current
ITRSMSM
1500
A
TC = 85 °C
TC = 47 °C
Dauergrenzstrom
ITAVM
599
960
A
A
average on-state current
Tvj = 25°C, tp = 10 ms
Tvj = Tvj max, tp = 10 ms
Stoßstrom-Grenzwert
surge current
ITSM
11.300
10.000
A
A
A²s*103
A²s*103
Tvj = 25°C, tp = 10ms
Tvj = Tvj max, tp = 10ms
Grenzlastintegral
I²t-value
I²t
638
500
Kritische Stromsteilheit
DIN IEC 747-6
f=50 Hz, iGM = 1 A
diG/dt = 1 A/µs
(diT/dt)cr
200
A/µs
critical rate of rise of on-state current
Tvj = Tvj max, vD = 0,67 VDRM
Kritische Spannungssteilheit
(dvD/dt)cr
1)
50
2)
critical rate of rise of off-state voltage
5. Kennbuchstabe / 5th letter B
5. Kennbuchstabe / 5th letter C
5. Kennbuchstabe / 5th letter L
5. Kennbuchstabe / 5th letter M
50
V/µs
500
500
1000
500 V/µs
50 V/µs
500 V/µs
Charakteristische Werte / Characteristic values
Tvj = Tvj max, iT = 1000 A
Durchlaßspannung
on-state voltage
vT
max. 1,66
1,15
V
Tvj = Tvj max
Schleusenspannung
threshold voltage
VT(TO)
V
mW
Tvj = Tvj max
Ersatzwiderstand
slope resistance
rT
0,42
Tvj = 25°C, vD =12 V
Tvj = 25°C, vD = 12V
Zündstrom
IGT
VGT
IGD
VGD
IH
max. 250
max. 2,2
mA
V
gate trigger current
Zündspannung
gate trigger voltage
Tvj = Tvj max, vD = 12 V
Nicht zündener Steuerstrom
gate non-trigger current
max. 10
max. 5
mA
mA
Tvj = Tvj max,vD = 0,5 VDRM
Tvj = Tvj max,vD = 0,5 VDRM
Nicht zündene Steuerspannung
gate non-trigger voltage
max. 0,25
max. 250
max. 1000
V
Tvj = 25°C, vD = 12 V, RA = 10 W
Haltestrom
mA
mA
holding current
Tvj = 25°C, vD = 12 V, RGK>= 10 W
iGM = 1 A, diG/dt = 1 A/µs
tg = 20 µs
Einraststrom
IL
latching current
Tvj = Tvj max
Vorwärts- und Rückwärts-Sperrstrom
forward off-state and reverse currents
iD, iR
max. 100
max. 1,5
mA
µs
vD = VDRM, vR = VRRM
Zündverzug
DIN IEC 747-6
tgd
Tvj = 25°C
gate controlled delay time
iGM = 1 A, diG/dt = 1 A/µs
1) Werte nach DIN IEC 747-6 (ohne vorausgehende Kommutierung). / Values to DIN IEC 747-6 (without prior commutation).
2) Unmittelbar nach der Freiwerdezeit, vgl. Meßbedingungen für tq ./ Immediately after circuit commutated turn-off-time,
see parameters tq.
SZ-M / 12.10.98 , K.-A. Rüther
A 117 / 98
Seite/page 1