DESIGNED & DIMENSIONED
IN MILLIMETERS[INCHES]
REVISION M
T2SDX-XX-XXX-XX-XX.XX-XX-XXX
TEFLON CABLE OPTION
-NXX OPTION (END 2)
(ONLY AVAILABLE WITH -D, -T, & -TR)
-NUS: NOTCH UP, STRAIGHT
(PIN 1 TO N-1)
-NDS: NOTCH DOWN, STRAIGHT
(PIN 1 TO 2)
FIG 1
-T: TEFLON (AVAILABLE WITH
24, 28, 30 AWG ONLY)
(LEAVE BLANK FOR STANDARD
PVC INSULATION)
DO NOT
SCALE FROM
THIS PRINT
T2SDX-05-24-X-XX.XX-S SHOWN
(No OF POS - 1) X 2.00[.079]
(SEE NOTE 10)
(No OF POS X 2.00[.079])
+ 0.55[.022]) REF
-NUX: NOTCH UP, CROSSED
(PIN 1 TO N)
-NDX: NOTCH DOWN, CROSSED
(PIN 1 TO 1)
No OF POSITONS
-02, -04, -05, -07, -10, -15, -20,
-25, & -30 (PER ROW)
AVAILABLE AS STANDARD
-05 THRU -50 AVAILABLE AS ASO
N (SEE TABLE 1)
(No OF POS X 2.00[.079])
+ 4.75[.187] REF
02
WIRE GAUGE (AWG)
-24, -26, -28,& -30
END OPTION
-S: SINGLE ENDED (SEE FIG 1)
7.50 .295
REF
7.70 .303
REF
-D: DOUBLE ENDED (SEE FIG'S 2, 3, 4, & 5)
-T: TRANSFER ENDED (SEE FIG'S 6, 7, 8, & 9)
-TR: TRANSFER ENDED WITH RETENTION
LATCH (SEE FIG'S 10, 11, 12, & 13)
7.00 .276
COLOR CODE:
REF
(LEAVE BLANK FOR ALL BLACK WIRE)
**-C: COLOR CODED WIRE, SEE TABLE 3,
SHEET 3 FOR COLOR SEQUENCE
(AVAILABLE WITH 24 AWG ONLY
AND NOT AVAILABLE WITH TEFLON)
01
N-1 (SEE TABLE 1)
ASSEMBLED LENGTH
SPECIFY IN INCHES
SINGLE ENDED: 03.00 INCH MINIMUM
DOUBLE ENDED: 03.25 INCH MINIMUM
PLATING SPECIFICATION
3.53 .139 REF (TYP)
-L: 10µ" LIGHT SELECTIVE GOLD IN CONTACT
AREA, BRIGHT ACID TIN ON TAIL
-S: 30µ" SELECTIVE GOLD IN CONTACT AREA,
BRIGHT ACID TIN ON TAIL
POS 01 INDICATOR
(No OF POS X 2.00[.079])
+ 2.15[.085] REF
-F: 3µ" FLASH GOLD IN CONTACT AREA,
BRIGHT ACID TIN ON TAIL
"A"
4.14 .163
3.42 .135 (TYP)
ITD2-XX-D
REF
15.40 .606
REF
C
ASSEMBLED LENGTH
(SEE NOTE 8 & 11)
DWC-XX-XX-300
OR DWCT-XX-01
1.30 .051
REF (TYP)
"A"
SECTION "A"-"A"
NOTES:
C
1.
REPRESENTS A CRITICAL DIMENSION.
2. MINIMUM PULLOUT FORCE: 2.5 LBS [11.1 N].
3. CONTACTS MUST BE INSERTED UNTIL RETENTION
FEATURES LOCK INTO PLACE.
4. ALL FINISHED GOODS ARE TO BE ELECTRICALLY
TESTED INCLUDING HI-POT TEST AT 1000 VOLTS DC.
AFTER FINAL ELECTRICAL TEST, LABEL EACH ASSEMBLY WITH
(1) LABEL-ET STAMP ON THE BODY.
C
C
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS CONFIDENTIAL AND
*
*
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN MILLIMETERS.
TOLERANCES ARE:
PROPRIETARY INFORMATION AND ALL DESIGN,
MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS
AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC,
INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE
OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR
REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY
OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS
WRITTEN CONSENT OF SAMTEC, INC.
DECIMALS
ANGLES
X.X: 0.3 [.01]
2
5. TINNED COPPER WIRE IS RoHS COMPLIANT.
6. PARTS TO BE LAYER PACKAGED.
520 PARK EAST BLVD, NEW ALBANY, IN 47150
X.XX: 0.13 [.005]
PHONE: 812-944-6733
e-Mail info@SAMTEC.com
FAX: 812-948-5047
code 55322
X.XXX: 0.051 [.0020]
7. END OF DISCRETE WIRE MUST FALL WITHIN THIS RANGE AFTER CRIMP.
8. FOR LENGTHS OF 12.00 INCHES AND LESS, TOLERANCE TO BE ± 3.18[.125],
FOR LENGTHS GREATER THAN 12.00 INCHES, TOLERANCE TO BE ± 2%
9. REFER TO CRIMP SPECIFICATIONS PRINT FOR CRIMP AND STRIP DIMENSIONS,
TOLERANCES, AND TOOLING.
SHEET SCALE: 2:1
DO NOT SCALE DRAWING
DESCRIPTION:
MATERIAL:
2.00mm TERMINAL DISCRETE CABLE ASSM.
DWG. NO.
INSULATOR: LCP, COLOR: BLACK
TERMINAL: PHOS BRONZE
CABLE INSULATION: SEE CALLOUT
WIRE: TINNED COPPER
T2SDX-XX-XXX-XX-XX.XX-XX-XXX
10. ASSEMBLIES USING THE FEP OPTION ARE FOR CRIMP APPLICATIONS ONLY.
11. CUT LENGTH IS ASSEMBLY LENGTH MINUS OVERALL LENGTH SUBTRACTOR.
SHEET 1 OF
4
BY: J. BORGELT
5/18/09
F:\DWG\MISC\MKTG\T2SDX-XX-XXX-XX-XX.XX-XX-XXX-MKT.SLDDRW