Low Profile International Series Power Transformer
Secondary Ratings
--- Series --- --- Parallel ---
Dual Primaries: 115/ 230V, 50/ 60 Hz
Part
3 Flange Bobbin Design
Number
VA
V
I(Amps) V I (Amps)
6 VA Ratings -- Hi-Pot 4000 VRMS
T-61001
T-61002
T-61003
T-61004
T-61005
T-61006
T-61007
T-61008
T-61009
T-61010
T-61011
T-61012
T-61013
T-61014
T-61015
T-61016
T-61017
T-61018
T-61019
T-61020
T-61021
T-61022
T-61023
T-61024
T-61025
T-61026
T-61027
T-61028
T-61029
T-61030
T-61031
T-61032
T-61033
T-61034
T-61035
T-61036
T-61037
T-61038
T-61039
T-61040
T-61041
T-61042
2.5
5.0
10.0
10.0
10.0
10.0
10.0
10.0
12.6
12.6
12.6
12.6
12.6
12.6
16.0
16.0
16.0
16.0
16.0
16.0
20.0
20.0
20.0
20.0
20.0
20.0
24.0
24.0
24.0
24.0
24.0
24.0
28.0
28.0
28.0
28.0
28.0
28.0
36.0
36.0
36.0
36.0
36.0
36.0
0.25
0.5
1.0
2.0
3.0
5.6
0.2
0.4
0.8
1.6
2.4
4.4
0.15
0.31
0.62
1.25
1.9
5.0
5.0
5.0
5.0
5.0
0.5
1.0
2.0
4.0
6.0
10.0
20.0
30.0
56.0
2.5
FOR 2.5 T0 56.0 VA
Parallel External
Connections:
L
W
6-3, 1-4 & 10-7, 9-12
5.0 11.2
6.3
6.3
6.3
6.3
6.0
6.0
8.0
8.0 0.62
8.0 1.25
8.0
8.0
8.0
0.4
0.8
1.6
3.2
4.8
8.8
0.3
Series External
Connections:
4-3 & 9-10
H
PRIMARY
5.0
4
6
1
3
10.0
20.0
30.0
56.0
2.5
B
C
A
A
5.0
Schematic
10.0
20.0
30.0
56.0
2.5
F
6
7
2.5
3.8
7.0
4
3
9
3.5
0.12 10.0 0.24
0.25 10.0 0.5
10
E
5.0
1
12
10.0
20.0
12.0
56.0
2.5
0.5
1.0
1.5
2.8
0.1
10.0 1.0
10.0 2.0
10.0 3.0
10.0 5.6
12.0 0.2
FOR 2.5 T0 10.0 VA
FOR 2.5 TO 10.0 SERIES
B
A
A
6
7
10
12
7
9
4
3
9
.187 MIN
(4.75)
5.0
0.21 12.0 0.42
0.42 12.0 0.84
0.83 12.0 1.66
1.25 12.0 2.5
2.33 12.0 4.66
0.09 14.0 0.18
0.18 14.0 0.36
0.36 14.0 0.72
0.72 14.0 1.44
1.06 14.0 2.12
10
SECONDARY
10.0
20.0
30.0
56.0
2.5
11
12
1
FOR 20.0 TO 56.0 SERIES
FOR 20.0 T0 56.0 VA
A
D
A A
5.0
10.0
20.0
30.0
56.0
2.5
Materials used in construction of
this component meet or exceed
UL Class B and can be operated
up to 130o C
9
10 11
12
7
SECONDARY
2.0
14.0 4.0
0.07 18.0 0.14
0.14 18.0 0.28
0.28 18.0 0.56
0.56 18.0 1.12
0.82 18.0 1.64
1.56 18.0 3.12
4 000 Volts RMS Hipot Test - Dual
Non-concentric Bobbins and insulating
Shroud Provide High Isolation and
Reduced Capacitance
5.0
10.0
20.0
30.0
56.0
Size
(VA)
Dimension in Inches
L
W
H
A*
B
C
D
E
F
NON-CONCENTRIC WINDING:
Primary and Secondary are wound
side-by-side rather than layered.
The added isolation reduces inter-
winding capacitance, eliminating
the need for an electro-static shield.
Additionally, it reduces radiated
magnetic fields.
2.5 1.625 1.313 1.125 .200 .250 1.000
5.0 1.625 1.313 1.375 .200 .400 1.000
10.0 1.875 1.563 1.375 .200 .400 1.140
1.063
1.063
1.250
1.500
20.0 2.250 1.875 1.625 .400 .400 1.460 .40
30.0 2.625 2.188 1.563 .550 .275 1.680 .55
56.0 3.000 2.500 1.813 .600 .300 1.900 .60
1.75 2.19
2.00 2.50
* For 20.0 TO 56.0 series secondary only, dimensions A is 1/ 2 of value shown
INTL-PC 11/98
Specifications are subject to change without notice
15801 Che m ic a l La ne
Hunting to n Be a c h, Ca lifo rnia 92649-1595
Pho ne : (714) 898-0960 • FAX: (714) 896-0971
Rh om bu s
In du st ries In c.
www.rhombus-ind.com
Tra nsformers & Ma gnetic Products