version:V2.3
Miniature
Power Relay
SANYOU RELAYS
SRD(I)-L-Series
Relays for advanced technology
Features
●High contact capability: 12A switching capability.
●Low coil power consumption, low price.
●Microminiature relay, standard PCB terminal.
●Compliance with RoHs and requirement for White Goods.
●
Compliance
with IEC60335-1 GWIF 850℃/GWIT 775℃
and CTI>=250V。
●
●
Impulse withstand voltage≥6000V product is available.
Satisfy IEC60079-15 product is available
.
Safety Approval
UL,C-UL File No.:E190598
VDE File No.: 40034479
CQC File No.:CQC02001002126
Contact Capacity
Model
SRD(I) -D-L
SRD(I) -DM-L
12A 277VAC
Nominal switching
capacity (res. load)
NO12A 277VAC
NO/NC7A 277VAC
20A
Max. switching current
Max. switching voltage
Max. switching power
20A
277VAC
5,540VA
277VAC
5,540VA
Characteristic Data
Contact material
silver alloy
Initial contact resistance (at 6VDC 1A)
100mΩ Max. (1A 6VDC)
8msec. Max. (no diode)
5msec. Max. (no diode)
100MΩ Min.(DC500V)
Operate time (at nominal volt.)
Release time (at nominal volt.)
Initial insulation resistance
Between open contacts: AC 750V,50/60Hz 1min.
Between coil and contact: standard product AC 1,500V,50/60Hz 1min
SRD
Between coil and contact: standard product AC 2,500V,50/60Hz 1min
product with suffix"-6" : AC3000V,50/60Hz 1min
Initial dielectric strength
SRDI
Between coil and contact: standard product ≥4800V 1.2/50us
product with suffix"-6" ≥6000V 1.2/50us
Impulse withstand voltage
SRDI
10~55Hz at double amplitude of 1.5 mm
10~55Hz ouble mplitude 1.5 mm
Function
Destructive
Function
Vibration resistance
Shock resistance
at
d
a
od
10G Min.
100G Min.
10,000,000
Destructive
Mechanical(at 10,800ops./H)
Endurance
(operations)
Electrical(at 360ops./H)
50,000 (at 105℃)
Ambient temperature
Unit weight
-40℃~+105℃(no condensation)
Approx.8.5g
1/3