Ordering information
AC-DC Power Supplies Open Frame/Enclosed Value-added Type
SPLF A
30
F
-O -O
5 6
SPLFA30F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional
C: with Coating
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
SPLFA30F-5
30.0
5V 6A
SPLFA30F-12
30.0
12V 2.5A
SPLFA30F-24
31.2
24V 1.3A
SPECIFICATIONS
MODEL
SPLFA30F-5
SPLFA30F-12
SPLFA30F-24
*3
VOLTAGE[V]
AC85 - 264 1f(Refer to Instruction Manual 1.1 and 3.1)
ACIN 100V 0.65typ (Io=100%)
ACIN 200V 0.35typ (Io=100%)
50 / 60 (47 - 440)
CURRENT[A]
FREQUENCY[Hz]
INPUT
ACIN 100V 75.0typ
78.0typ
80.0typ
81.0typ
83.0typ
EFFICIENCY[%]
ACIN 200V 77.0typ
ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C)
ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C)
INRUSH CURRENT[A]
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.30 / 0.65max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
5
12
24
CURRENT[A]
6.0
2.5
1.3
*5
*5
*1
LINE REGULATION[mV]
LOAD REGULATION[mV]
20max
100max
100max
140max
250max
300max
48max
100max
120max
160max
250max
300max
120max
150max
48max
96max
150max
120max
160max
250max
300max
240max
290max
96max
0 to +50C
RIPPLE[mVp-p]
*1
-10 - 0C
*1
0 to +50C
OUTPUT
RIPPLE NOISE[mVp-p]
*1
-10 - 0C
0 to +50C 50max
TEMPERATURE REGULATION[mV]
-10 to +50
C
60max
20max
*
2
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE SETTING[V]
150typ (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
4.90 to 5.30
11.50 to 12.50
23.00 to 25.00
27.60 to 33.60
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V] 5.75 to 7.00 13.80 to 16.80
PROTECTION
CIRCUIT AND OPERATING INDICATION
LED (Green)
Not provided
Not provided
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
ISOLATION INPUT-FG
OUTPUT-FG
*3
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
ENVIRONMENT
2
VIBRATION
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axis
AGENCY APPROVALS
CONDUCTED NOISE/POWER Complies with DEN-AN
DEN-AN
SAFETY AND
NOISE
REGULATIONS
*
4
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
Complies with IEC61000-3-2 class A (Not built-in to active filter)
61X36X150mm [2.40X1.42X5.91 inches] (WXHXD) / 370g max
Convection
OTHERS
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*3 Derating is required.
*4 When two or more units are operating it may not comply with the IEC61000-3-2. Please contact us about another class.
*5 Please contact us about dynamic load and input response.
*
*
*
*
To meet the specifications. Do not operate over-loaded condition.
Parallel operation is not possible.
Derating is required when operated with chassis and cover.
Sound noise may be generated by power supply in case of pulse load.
M arch 13, 2019
SPLFA-2