R
SPECIFICATION
MODEL
SP-200-3.3 SP-200-5
SP-200-7.5 SP-200-12 SP-200-13.5 SP-200-15 SP-200-24 SP-200-27 SP-200-48
DC�VOLTAGE
3.3V
5V
7.5V
12V
13.5V
15V
24V
27V
48V
RATED�CURRENT
CURRENT�RANGE
RATED�POWER
40A
40A
26.7A
16.7A
14.9A
13.4A
8.4A
7.5A
4.2A
0�~�40A
132W
0�~�40A
200W
100mVp-p
0�~�26.7A
200.2W
100mVp-p
0�~�16.7A
200.4W
100mVp-p
0�~�14.9A
201.1W
100mVp-p
0�~�13.4A
201W
0�~�8.4A
201.6W
150mVp-p
0�~�7.5A
202.5W
150mVp-p
0�~�4.2A
201.6W
250mVp-p
RIPPLE�&�NOISE�(max.) Note.2 100mVp-p
VOLTAGE ADJ.�RANGE
VOLTAGE�TOLERANCE Note.3 2.0%
100mVp-p
OUTPUT
3.14�~�3.63V 4.75�~�5.5V 7.13�~�8.25V 11.4�~�13.2V 12.8�~�14.9V 14.3�~�16.5V 22.8�~�26.4V 25.7�~�29.7V 45.6�~�52.8V
2.0%
0.5%
1.0%
2.0%
0.5%
1.0%
2.0%
0.5%
0.5%
2.0%
0.5%
0.5%
2.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
LINE�REGULATION
LOAD�REGULATION
SETUP,�RISE�TIME
HOLD�TIME (Typ.)
0.5%
1.0%
600ms,�30ms�at�full�load
20ms�at�full�load
VOLTAGE�RANGE
85�~�264VAC����������120�~�370VDC
47�~�63Hz
FREQUENCY RANGE
POWER�FACTOR (Typ.)
EFFICIENCY (Typ.)
PF>0.93/230VAC����������PF>0.98/115VAC�at�full�load
65% 71% 76% 79%
80%
81%
83%
83%
84%
INPUT
3.5A/115VAC��������1.7A/230VAC
COLD�START 40A/230VAC
<2mA /�240VAC
AC�CURRENT (Typ.)
INRUSH�CURRENT (Typ.)
LEAKAGE�CURRENT
105�~�150% rated�output�power
OVER�LOAD
Protection�type�:�Constant�current�limiting,�recovers�automatically�after�fault�condition�is�removed
3.63�~�4.46V 5.5�~�6.75V 8.25�~�10.13V 13.2�~�16.2V 14.85�~�18.2V 16.5�~�20.25V 26.4�~�32.4V 29.7�~�36.45V 52.8�~�64.8V
Protection�type�:�Shut�down�o/p�voltage,�re-power�on�to�recover
OVER�VOLTAGE
PROTECTION
95
5
(TSW1�:�Detect�on�heatsink�of�power�transistor)
OVER�TEMPERATURE
Protection�type�:�Shut�down�o/p�voltage,�recovers�automatically�after�temperature�goes�down
CN1:4�~�10VDC�POWER�ON,�<0�~�0.8VDC�POWER�OFF
-10�~�+60 (Refer�to�output�load�derating�curve)
20�~�90%�RH�non-condensing
FUNCTION REMOTE�CONTROL(OPTION)
WORKING�TEMP.
WORKING�HUMIDITY
-20�~�+85 ,�10�~�95%�RH
STORAGE�TEMP.,�HUMIDITY
TEMP.�COEFFICIENT
VIBRATION
ENVIRONMENT
0.05%/ (0�~�50
10�~�500Hz,�2G�10min./1cycle,�60min.�each�along�X, Y,�Z�axes
UL60950-1, TUV�EN60950-1�and�S-MARK�J60950 Approved
I/P-O/P:3KVAC�����I/P-FG:1.5KVAC�����O/P-FG:0.5KVAC
I/P-O/P,�I/P-FG,�O/P-FG:100M�Ohms/500VDC
Compliance�to�EN55022�(CISPR22)�Class�B
SAFETY STANDARDS
WITHSTAND�VOLTAGE
ISOLATION�RESISTANCE
EMI�CONDUCTION�&�RADIATION
HARMONIC�CURRENT
EMS�IMMUNITY
SAFETY &
EMC
(Note�4)
Compliance�to EN61000-3-2,-3
Compliance�to�EN61000-4-2,3,4,5,6,8,11;�ENV50204,�EN55024,�Light�industry�level,��criteria A
MTBF
183.8K�hrs�min.������MIL-HDBK-217F�(25
199*99*50mm�(L*W*H)
)
OTHERS
NOTE
DIMENSION
0.85Kg;�20pcs/17.9Kg/1.28CUFT
PACKING
ꢫꢚꢈꢉꢇꢇꢈꢋꢆꢄꢆꢢꢃꢍꢃꢄꢅꢈꢤꢠꢹꢈꢅꢋꢃꢓꢁꢆꢇꢇꢰꢈꢢꢃꢀꢍꢁꢖꢀꢃꢡꢈꢆꢄꢃꢈꢢꢃꢆꢅꢌꢄꢃꢡꢈꢆꢍꢈꢺꢜꢙꢻꢉꢊꢈꢁꢀꢋꢌꢍꢗꢈꢄꢆꢍꢃꢡꢈꢇꢖꢆꢡꢈꢆꢀꢡꢈꢺꢼ ꢖꢏꢈꢆꢢꢭꢁꢃꢀꢍꢈꢍꢃꢢꢋꢃꢄꢆꢍꢌꢄꢃꢚ
ꢺꢚꢈꢣꢁꢋꢋꢇꢃꢈꢽꢈꢀꢖꢁꢅꢃꢈꢆꢄꢃꢈꢢꢃꢆꢅꢌꢄꢃꢡꢈꢆꢍꢈꢺꢙꢷꢴꢵꢈꢖꢏꢈꢭꢆꢀꢡꢪꢁꢡꢍꢟꢈꢭꢰꢈꢌꢅꢁꢀꢐꢈꢆꢈꢫꢺꢾꢈꢍꢪꢁꢅꢍꢃꢡꢈꢋꢆꢁꢄꢒꢪꢁꢄꢃꢈꢍꢃꢄꢢꢁꢀꢆꢍꢃꢡꢈꢪꢁꢍꢟꢈꢆꢈꢙꢚꢫꢌꢏꢈꢽꢈꢸꢲꢌꢏꢈꢋꢆꢄꢆꢇꢇꢃꢇꢈꢓꢆꢋꢆꢓꢁꢍꢖꢄꢚ
ꢜꢚꢈꢹꢖꢇꢃꢄꢆꢀꢓꢃꢈꢝꢈꢁꢀꢓꢇꢌꢡꢃꢅꢈꢅꢃꢍꢈꢌꢋꢈꢍꢖꢇꢃꢄꢆꢀꢓꢃꢗꢈꢇꢁꢀꢃꢈꢄꢃꢐꢌꢇꢆꢍꢁꢖꢀꢈꢆꢀꢡꢈꢇꢖꢆꢡꢈꢄꢃꢐꢌꢇꢆꢍꢁꢖꢀꢚ
ꢸꢚꢈꢹꢟꢃꢈꢋꢖꢪꢃꢄꢈꢅꢌꢋꢋꢇꢰꢈꢁꢅꢈꢓꢖꢀꢅꢁꢡꢃꢄꢃꢡꢈꢆꢈꢓꢖꢢꢋꢖꢀꢃꢀꢍꢈꢪꢟꢁꢓꢟꢈꢪꢁꢇꢇꢈꢭꢃꢈꢁꢀꢅꢍꢆꢇꢇꢃꢡꢈꢁꢀꢍꢖꢈꢆꢈꢏꢁꢀꢆꢇꢈꢃꢯꢌꢁꢋꢢꢃꢀꢍꢚꢈꢹꢟꢃꢈꢏꢁꢀꢆꢇꢈꢃꢯꢌꢁꢋꢢꢃꢀꢍꢈꢢꢌꢅꢍ ꢭꢃꢈꢄꢃꢒꢓꢖꢀꢏꢁꢄꢢꢃꢡꢈꢍꢟꢆꢍꢈꢁꢍꢈꢅꢍꢁꢇꢇꢈꢢꢃꢃꢍꢅ
ꢨꢷꢊꢈꢡꢁꢄꢃꢓꢍꢁꢂꢃꢅꢚ
300 Myleꢀ standiꢀh Blvd., Taunton, MA 02780
WWW.AsTRODYNE.COM
ph: 1-800-823-8082
Fax: 508-823-8181