100W Single Output with PFC Function
SP-100 series
■ Features :
#Universal AC input / full range
#Built-in active PFC function, PF>0.93
#Protections: Short circuit / Overload / Over voltage
#Built-in constant current limiting circuit
#Remote ON-OFF control(Optional)
#LED indicator for power on
#100% full load burn-in test
#Fixed switching frequency at PFC:67KHz PWM:134KHz
#3 years warranty
..
SPECIFICATION
MODEL
SP-100-3.3 SP-100-5
SP-100-7.5 SP-100-12 SP-100-13.5 SP-100-15 SP-100-24 SP-100-27 SP-100-48
DC VOLTAGE
3.3V
5V
7.5V
12V
13.5V
15V
24V
27V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
20A
20A
13.5A
8.5A
7.5A
6.7A
4.2A
3.8A
2.1A
0 ~ 20A
66W
0 ~ 20A
100W
100mVp-p
0 ~ 13.5A
101.25W
100mVp-p
0 ~ 8.5A
102W
0 ~ 7.5A
101.25W
100mVp-p
0 ~ 6.7A
100.5W
100mVp-p
0 ~ 4.2A
100.8W
150mVp-p
0 ~ 3.8A
102.6W
150mVp-p
0 ~ 2.1A
100.8W
250mVp-p
RIPPLE & NOISE (max.) Note.2 100mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 2.0%
100mVp-p
OUTPUT
3.14 ~ 3.63V 4.75 ~ 5.5V 7.13 ~ 8.25V 11.4 ~ 13.2V 12.8 ~ 14.9V 14.3 ~ 16.5V 22.8 ~ 26.4V 25.7 ~ 29.7V 45.6 ~ 52.8V
2.0%
0.5%
1.0%
2.0%
0.5%
1.0%
2.0%
0.5%
0.5%
2.0%
0.5%
0.5%
2.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
0.5%
1.0%
600ms, 30ms at full load
20ms at full load
VOLTAGE RANGE
85 ~ 264VAC
47 ~ 63Hz
120 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
PF>0.93/230VAC
PF>0.98/115VAC at full load
78% 80%
0.8A/230VAC
INPUT
70%
76%
80%
82%
84%
83%
82%
1.7A/115VAC
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
COLD START 30A/230VAC
<2mA / 240VAC
LEAKAGE CURRENT
105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVERLOAD
PROTECTION
3.63 ~ 4.46V 5.5 ~ 6.75V 8.25 ~ 10.13V 13.2 ~ 16.2V 14.85 ~ 18.23V 16.5 ~ 20.25V 26.4 ~ 32.4V 29.7 ~ 36.45V 52.8 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
CN1:4 ~ 10VDC POWER ON, <0 ~ 0.8VDC POWER OFF
-10 ~ +60℃ (Refer to output load derating curve)
20 ~ 90% RH non-condensing
OVER VOLTAGE
FUNCTION REMOTE CONTROL(OPTION)
WORKING TEMP.
WORKING HUMIDITY
-20 ~ +85℃, 10 ~ 95% RH
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
ENVIRONMENT
0.05%℃/ (0 ~ 5℃0 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Compliance to EN55022 (CISPR22) Class B
SAFETY &
EMC
(Note 4)
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
211.3K hrs min. MIL-HDBK-217F (25℃)
MTBF
OTHERS
NOTE
DIMENSION
179*99*45mm (L*W*H)
0.66Kg; 20pcs/14.3Kg/1.17CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:SP-100-SPEC 2007-10-25