SN65HVD255
SN65HVD256, SN65HVD257
www.ti.com
SLLSEA2B –DECEMBER 2011–REVISED JUNE 2012
CAN Transceivers with Fast Loop Times for Highly Loaded Networks and Features For
Functional Safety Networks
Check for Samples: SN65HVD255, SN65HVD256, SN65HVD257
1
FEATURES
DESCRIPTION
This CAN transceiver meets the ISO1189-2 High
Speed CAN (Controller Area Network) Physical Layer
standard. It is designed for data rates in excess of 1
megabit per second (Mbps) in short networks, and
enhanced timing margin and higher data rates in long
and highly-loaded networks. The device provides
many protection features to enhance device and
CAN-network robustness. The SN65HVD257 adds
additional features, allowing easy design of redundant
and multi-topology networks with fault indication for
higher levels of functional safety in the CAN system.
•
•
Meets the Requirements of ISO11898-2
'Turbo CAN': Short Propagation Delay Times
and Fast Loop Times; Higher Data Rates in
Network; Enhances System Timing Margins
•
•
I/O Voltage Range Supports 3.3V and 5V MCUs
Ideal Passive Behavior When Unpowered
–
Bus Pins are High Impedance (no load to
operating bus)
–
–
Logic Pins are High Impedance
Power Up/Down With Glitch Free Operation
On Bus
NC / VRXD / FAULT (See Note A)
5
VCC
3
FAULT LOGIC
•
Protection Features:
MUX (See Note A)
VCC
OVER
TEMPERATURE
–
ESD Protection of Bus Pins
HBM ESD Protection Exceeds ±12kV
VCC
–
7
6
CANH
CANL
DOMINANT
TIME OUT
1
8
TXD
–
–
–
–
Bus Fault Protection –27V to 40V
Undervoltage Protection on Supply Pins
Driver Dominant Time Out (TXD DTO)
S
MODE SELECT
SN65HVD257: Receiver Dominant Time Out
(RXD DTO)
UNDER
VOLTAGE
–
–
SN65HVD257: FAULT Output Pin
Thermal Shutdown Protection
VCC or VRXD (See Note B)
DOMINANT
TIME OUT
(See Note B)
4
LOGIC
OUTPUT
RXD
•
Characterized for –40°C to 125°C Operation
2
GND
APPLICATIONS
A. Pin 5 function is device dependent; NC on
SN65HVD255, VRXD for RXD output level-
shifting device on SN65HVD256, and
FAULT Output on SN65HVD257
•
1Mbps Operation in Highly Loaded CAN
Networks Down to 10kbps Networks Using
TXD DTO
B. RXD logic output is driven to 5V VCC on
5V-only supply devices (SN65HVD255,
SN65HVD257) and driven to VRXD on
output level-shifting device (SN65HVD256).
•
Industrial Automation, Control, Sensors and
Drive Systems
•
•
•
•
Building and Climate Control Automation
Security Systems
C. RXD (Receiver) Dominant State Time Out
is a device dependent option available only
on SN65HVD257.
Telecom Base Station Status and Control
SN65HVD257: Functional Safety With
Redundant and Multi-topology CAN networks
Figure 1. Functional Block Diagram
•
CAN Bus Standards Such as CANopen,
DeviceNet, NMEA2000, ARNIC825, ISO11783,
CAN Kingdom, CANaerospace
1
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.
Copyright © 2011–2012, Texas Instruments Incorporated