300/400 Watts
SMQ Series
xppower.com
•
•
•
•
•
•
•
High Power Density
High Peak Load Rating
DC OK
Remote On/Off
Universal Input
Single Outputs from 12.0 V to 54.0 V
Internal Fan
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• 90-264 VAC (120-370 VDC)
Efficiency
Isolation
• 80% typical
• 47-63 Hz
• 3000 VAC Input to Output,
1500 VAC Input to Ground,
250 VDC Output to Ground
• 5.00 A at 90 VAC (SMQ300),
6.35 A at 90 VAC (SMQ400)
Switching Frequency
• 60 kHz typical for PFC stage,
30 kHz typical for main converter
• 4.7 W/In3 (SMQ300), 6.25 W/In3 (SMQ400)
Inrush Current
Power Factor
• 35 A max at 230 VAC
• 0.99 typical
Power Density
Signals
Earth Leakage Current • <2.5 mA at 230 VAC/50Hz
• DC OK, TTL HIGH within 100-500 ms
LOW 1 ms before loss of regulation
<1.5 mA at 115 VAC/60Hz
MTBF
• 138 kHrs per MIL-HDBK-217F
Output
Output Voltage
Output Voltage Trim
Minimum Load
Start Up Delay
• 12 to 54 VDC - see table
• See table
Environmental
Operating Temperature • 0 ˚C to +70 ˚C, derate linearly from
• No minimum load required
• 2.5 s typical at 120 VAC
• 20 ms minimum at 120 VAC & 80% load
100% at +50 ˚C to 50% at +70 ˚C
Cooling
• Via internal fan
Hold Up Time
Operating Humidity
Storage Temperature
Shock
• 5-90% RH, non-condensing
• -20 ˚C to +85 ˚C
Line Regulation
Load Regulation
Transient Response
•
•
1%
1%
• 15 g (non-operation), 11 ms half
sine-wave, 3 times for each axis
• 5% max. deviation, recovery to within
1% in 500 µs for a 50% load change
Vibration
• 10 Hz - 55 Hz (non-operation) 2 g,
sweep time 3 mins, 60 mins/axis
Ripple & Noise
• 1% pk-pk, 20 MHz BW
Overvoltage Protection • 115-130% Vnom, recycle input to reset
Overcurrent Protection • 120-150% of nominal current,
EMC & Safety
auto recovery
Emissions
• EN55022 and FCC Part 15,
level B conducted
Overtemperature
Protection
• Unit shuts down, auto recovery
Harmonic Currents
Voltage Flicker
ESD Immunity
• EN61000-3-2
• EN61000-3-3
Remote Sense
Remote On/Off
• Compensates for up to 0.5 V drop
• On = TTL Logic High or Open circuit
Off = TTL Logic Low or Short circuit
• EN61000-4-2, level 2 contact, level 3 air,
Perf Criteria A
Radiated Immunity
EFT/Burst
• EN61000-4-3, 3 V/m, Perf Criteria A
• EN61000-4-4, level 2, Perf Criteria A
• EN61000-4-5, level 3, Perf Criteria A
• EN61000-4-6, level 2, Perf Criteria A
Surge
Conducted Immunity
Dips & Interruptions
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms Perf Criteria A, B, B
Safety Approvals
• UL60950, CSA C22.2 No.60950,
EN60950, CE Mark LVD