SMM766B  
PIN DESCRIPTIONS  
Pin  
Pin  
Pin Name  
Pin Description  
Number Type  
SDA (Serial Data) is an open drain bi-directional pin used as the I2C data  
line.  
1
2
DATA  
CLK  
SDA  
SCL  
SCL (Serial Clock) is an open drain input pin used as the I2C Clock line.  
The A2 (Address bit 2) pin is biased either to VDD_CAP or GND. When  
communicating with the SMM766B over the 2-wire I2C bus, A2 provides a  
mechanism for assigning a unique bus address.  
3
4
IN  
IN  
A2  
MR# (Manual Reset) is an active low input. When asserted the RST# output  
will become active. When de-asserted the RST# output will go inactive  
immediately after a reset timeout period (tRTO) if there are no RST# trigger  
sources active. This timeout period makes it suitable to use as a pushbutton  
for manual reset purposes.  
MR#  
PWR_ON (Power On) is an open drain bi-directional pin. On the rising edge  
of PWR_ON the part will sequence the supplies on, during the falling edge  
the part will sequence the supplies off. This pin must be tied high through an  
external pull-up resistor.  
Note: The SMM766B does not monitor for faults during power-on/off  
sequencing.  
5
6
I/O  
I/O  
PWR_ON  
FS# (Force Shutdown) is an open drain active low bi-directional pin. FS# is  
used to immediately turn off all converter enable signals (PUP outputs) when  
a fault is detected. Whenever FS# is asserted PWR_ON will automatically be  
pulled low as well. This pin must be tied high through an external pull-up  
resistor.  
FS#  
The FAULT# pin is an active low open drain output. Active when a  
programmed fault condition exists on AIN1, AIN2, or the internal temperature  
sensor. When used, FAULT# should be pulled high through an external pull-  
up resister.  
7
8
OUT  
OUT  
FAULT#  
HEALTHY is an active high open drain output. Active when all programmed  
power supply inputs and monitored inputs are within OV and UV limits and  
ADOC has begun. When used, HEALTHY should be pulled high through an  
external pull-up resistor.  
HEALTHY  
RST# (Reset) is an active low open drain output pin. Active when a  
programmed fault condition exists on any power supply inputs or monitored  
inputs, when MR# is active, or when ADOC is not ready. RST# has a  
programmable timeout period with options for 0.64ms, 25ms, 100ms and  
200ms. When used, RST# should be pulled high through an external pull-up  
resistor.  
9
OUT  
RST#  
10  
11  
12  
AIN1 (Analog Input 1) is a general-purpose monitored analog input.  
AIN2 (Analog Input 2) is a general-purpose monitored analog input.  
Ground.  
IN  
IN  
AIN1  
AIN2  
GND  
GND  
Summit Microelectronics, Inc  
2122 3.1 5/24/2011  
5

与SMM766B_11相关器件

型号 品牌 描述 获取价格 数据表
SMM766FCR0 SUMMIT Six-Channel Active DC Output Controller, Moni

获取价格

SMM766FCR1 SUMMIT Six-Channel Active DC Output Controller, Moni

获取价格

SMM766FCR2 SUMMIT Six-Channel Active DC Output Controller, Moni

获取价格

SMM766FCR3 SUMMIT Six-Channel Active DC Output Controller, Moni

获取价格

SMM766FCR4 SUMMIT Six-Channel Active DC Output Controller, Moni

获取价格

SMM766FCR5 SUMMIT Six-Channel Active DC Output Controller, Moni

获取价格