SLG59M1707V
2
A 125 °C Rated, 4 mm , 13 mΩ, 3.5 A Load Switch with Protection
Features and an Analog Current Monitor Output
Electrical Characteristics (continued)
TA = -40 °C to 125 °C(unless otherwise stated). Typical values are at TA = 25 °C
Parameter Description
Conditions
Min.
Typ.
Max.
Unit
50% ON to VOUT Ramp Start,
VDD = VIN = 5 V;
TON_Delay ON Delay Time
--
300
500
μs
RLOAD = 20 Ω; CLOAD = 10 μF
10% VOUT to 90% VOUT ↑;
VDD = VIN = 5 V;
RLOAD = 20 Ω; CLOAD = 10 μF
VOUT(SR) VOUT Slew Rate
2
1.2
--
2.85
1.8
3.8
2.4
9
V/ms
ms
50% ON to 90% VOUT ↑;
VDD = VIN = 5 V;
RLOAD = 20 Ω; CLOAD = 10 μF
TTotal_ON
Total Turn ON Time
50% ON to VOUT Fall Start;
VDD = VIN = 5 V;
RLOAD = 20 Ω; no CLOAD
TOFF_Delay OFF Delay Time
CLOAD Output Load Capacitance
ILIMIT
6.5
μs
CLOAD connected from VOUT to GND
VOUT > 0.25 V; RSET = 40 kΩ1
VOUT < 0.25 V
1
1.5
--
10
2
100
2.5
--
μF
A
Active Current Limit, IACL
Short-circuit Current Limit, ISCL
0.5
A
Abnormal Step Load Current event to
FAULT↓1
TFAULTLOW FAULT Assertion Time
5
5
8
8
12
12
ms
ms
Delay to FAULT↑ after fault
condition is removed1
TFAULTHIGH FAULT De-assertion Time
FAULTVOL FAULT Output Low Voltage
IFAULT = 1 mA
--
0.85
-0.3
--
0.2
--
--
VDD
0.3
250
--
V
V
ON_VIH
ON_VIL
High Input Voltage on ON pin
Low Input Voltage on ON pin
0
V
RDISCHRG Output Discharge Resistance
VDD = VIN = 5 V
210
150
130
Ω
THERMON Thermal shutoff turn-on temperature VDD = VIN = 5 V
THERMOFF Thermal shutoff turn-off temperature VDD = VIN = 5 V
--
°C
°C
--
--
Notes:
1. See Application Diagram on Page 15.
Datasheet
3-Feb-2022
Revision 1.05
Page 4 of 27
©2022 Renesas Electronics Corporation
CFR0011-120-01