500~600W Parallel (N+1) With PFC Function
SCP-600 series
Features :
AC input 180~260VAC only
PF> 0.98@ 230VAC
Protections: Short circuit / Overload / Over voltage / Over temperature
Built in remote sense function
Built-in remote ON-OFF control
Built-in power good signal output
Built-in parallel operation function(N+1)
Can adjust from 20~100% output voltage by external control 1-5V
Forced air cooling by built-in DC fan
3 years warranty
SPECIFICATION
ORDER NO.
SCP-600-05 SCP-600-09 SCP-600-12 SCP-600-15 SCP-600-18 SCP-600-24 SCP-600-36 SCP-600-48 SCP-600-60
SAFETY MODEL NO.
600S-P005 600S-P009 600S-P012 600S-P015 600S-P018 600S-P024 600S-P036 600S-P048 600S-P060
DC VOLTAGE
5V
9V
12V
15V
18V
24V
36V
48V
60V
RATED CURRENT
CURRENT RANGE
RATED POWER
100A
0 ~ 100A
500W
66A
50A
40A
33.3A
25A
16.6A
12A
10A
0 ~ 66A
594W
100mVp-p
0 ~ 50A
600W
120mVp-p
0 ~ 40A
600W
150mVp-p
0 ~ 33.3A
599W
0 ~ 25A
600W
240mVp-p
0 ~ 16.6A
597W
0 ~ 12A
576W
480mVp-p
0 ~ 10A
600W
500mVp-p
OUTPUT
RIPPLE & NOISE (max.) Note.2 100mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 1.5%
180mVp-p
360mVp-p
3.0% Typical adjustment by potentiometer
20%~100% adjustment by 1~5VDC external control
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
LINE REGULATION
LOAD REGULATION
0.5%
1.0%
SETUP, RISE, HOLD UP TIME 500ms, 250ms, 16ms at full load
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR
180 ~ 260VAC 260 ~ 370VDC see the derating curve
47 ~ 63Hz
>0.98 / 230VAC
EFFICIENCY (Typ.)
AC CURRENT
80%
82%
84%
85%
86%
89%
89%
90%
90%
INPUT
5.0A / 230VAC
60A / 230VAC
INRUSH CURRENT (max.)
LEAKAGE CURRENT (max.) 3.5mA / 240VAC
105 ~ 115% rated output power
OVERLOAD
Note. 4
Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover
110 ~ 135% Follow to output set up point
PROTECTION OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
>100 / measure by heat sink, near transformer
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-20 ~ +65 (Refer to output load derating curve)
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +85
10 ~ 95% RH
ENVIRONMENT
0.04% / (0 ~ 50
)
10 ~ 200Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, OP/FG:100M Ohms / 500VDC / 25 / 70% RH
SAFETY &
EMC
(Note. 5)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) class A
Compliance to EN61000-3-2,3
HARMONIC CURRENT
EMS IMMUNITY
POWER GOOD SIGNAL
SPECIAL FUNCTION
COOLING
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
Open collector of NPN transistor
DC Voltage Adj., remote sensing, remote control, parallel operation(refer to control terminal instruction manual)
By fan, >20% load or >50 fan on
OTHERS
NOTE
MTBF
74.9K hrs min. MIL-HDBK-217F(25
290*120*68mm (L*W*H)
)
DIMENSION
1.9kg ; 8pcs / 22kg / CARTON
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Current limiting 3 times(1.5s,3.0s,5.0s)Then intelligent auto recovery before shut down
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name: SCP-600-SPEC 2008-05-06