1500W Single Output With Parallel Function
SCN-1K5 series
Features :
AC input 200~260V only
Protections: Short circuit / Overload / Over voltage / Over temp.
High reliability/ Low ripple noise
Built-in remote sense function
Built-in remote ON-OFF control
Built-in parallel operation function
Can adjust from 20~100% output voltage by external control 1-5V
Forced air cooling by built-in DC fan
Case coating with paint
2 years warranty
SPECIFICATION
ORDER NO.
SCN-1K5-12
SCN-1K5-15
SCN-1K5-24
SCN-1K5-48
MODEL NO.
1K5S-N012
12V
1K5S-N015
15V
1K5S-N024
1K5S-N048
48V
DC VOLTAGE
24V
RATED CURRENT
CURRENT RANGE
RATED POWER
125A
100A
62.5A
32A
0 ~ 125A
1500W
0 ~ 100A
1500W
0 ~ 62.5A
0 ~ 32A
1536W
480mVp-p
1500W
OUTPUT
RIPPLE & NOISE (max.) Note.2 120mVp-p
150mVp-p
240mVp-p
VOLTAGE ADJ. RANGE
5.0% typical adjustment by potentiometer
20~100% adjustment by 1~5VDC external control
VOLTAGE TOLERANCE Note.3 1.0%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
LINE REGULATION
LOAD REGULATION
0.5%
0.5%
SETUP, RISE, HOLD UP TIME 800ms, 50ms, 16ms at full load
VOLTAGE RANGE
200 ~ 260VAC 290 ~ 370VDC
47 ~ 63Hz
FREQUENCY RANGE
EFFICIENCY (Typ.)
83%
84%
85%
87%
INPUT
15A / 230VAC
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
120A / 230VAC
3.5mA / 240VAC
110 ~ 135% rated output power
OVERLOAD
Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover
110 ~ 135% follow to output set up point
PROTECTION OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
>100 / measure by heat sink, near transformer
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +65 (Refer to output load derating curve)
20% ~ 90% RH non-condensing
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
ENVIRONMENT
-20 ~ +85 , 10 ~ 95% RH
0.04% / (0 ~ 50
)
10 ~ 200Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
Design refer to UL1950, CSA22.2, IEC60950
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P, I/P-FG:1500VAC
SAFETY &
I/P-O/P, I/P-FG, >100M Ohms / 500VDC / 25 / 70% RH
EMC
(Note. 4)
EMI CONDUCTION & RADIATION Design refer to FCC part 15 class A
HARMONIC CURRENT
EMS IMMUNITY
MTBF
----
----
60Khrs min. MIL-HDBK-217F (25
291*132*132mm (L*W*H)
4.75kg; 4pcs / 20kg / CARTON
)
DIMENSION
OTHERS
NOTE
PACKING
SPECIAL FUNCTION
DC voltage adj., Remote sensing, remote control, parallel operation (refer to terminal instruction manual)
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.Tolerence: includes set up tolerance, line regulation, load regulation.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:SCN-1K5-SPEC 2008-05-06