150W Single Output Switching Power Supply
SC-150 series
Features :
AC input range selectable by switch
Protections:Short circuit/Over load/Over voltage
Charger for lead-acid batteries
Built-in constant current limiting circuit
Built-in temperature compensation circuit
Alarm signal output(Optional)
Fixed switching frequency at 25KHz
2 years warranty
SPECIFICATION
MODEL
SC-150-13.5
SC-150-27
SC-150-54
DC VOLTAGE
13.5V
27V
54V
RATED CURRENT
CURRENT RANGE
RATED POWER
11.2A
5.6A
2.8A
0 ~ 11.2A
151.2W
0 ~ 5.6A
151.2W
240mVp-p
24 ~ 30V
1.0%
0 ~ 2.8A
151.2W
240mVp-p
48 ~ 56V
1.0%
RIPPLE & NOISE (max.) Note.2 180mVp-p
VOLTAGE ADJ. RANGE 12 ~ 15V
VOLTAGE TOLERANCE Note.3 1.0%
OUTPUT
LINE REGULATION
0.3%
0.2%
0.2%
LOAD REGULATION
SETUP, RISE, HOLD TIME
0.3%
0.2%
0.2%
100ms, 50ms, 20ms at full load
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
88 ~ 132VAC/176 ~ 264VAC selected by switch
47 ~ 63Hz
248 ~ 370VDC
83%
86%
86%
INPUT
3.2A/115VAC
COLD START 35A
<3.5mA / 240VAC
1.6A/230VAC
INRUSH CURRENT (max.)
LEAKAGE CURRENT
105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
15.53 ~ 18.23V 31.05 ~ 36.45V 62.1 ~ 72.9V
OVER LOAD
PROTECTION
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
VIBRATION
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
SAFETY & ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
EMC
(Note 4)
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
234.1K Hrs min. MIL-HDBK-217F (25
199*110*50mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
0.8Kg; 16pcs/13.9Kg/0.95CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:SC-150-SPEC 2004-12-01