5秒后页面跳转
S8980 PDF预览

S8980

更新时间: 2024-11-04 03:33:59
品牌 Logo 应用领域
HAMAMATSU /
页数 文件大小 规格书
7页 185K
描述
Front-illuminated FFT-CCDs for X-ray imaging

S8980 技术参数

是否Rohs认证: 符合生命周期:Active
Reach Compliance Code:unknown风险等级:5.75
峰值回流温度(摄氏度):NOT SPECIFIED技术:CMOS
处于峰值回流温度下的最长时间:NOT SPECIFIEDuPs/uCs/外围集成电路类型:DSP PERIPHERAL, CROSSBAR SWITCH
Base Number Matches:1

S8980 数据手册

 浏览型号S8980的Datasheet PDF文件第2页浏览型号S8980的Datasheet PDF文件第3页浏览型号S8980的Datasheet PDF文件第4页浏览型号S8980的Datasheet PDF文件第5页浏览型号S8980的Datasheet PDF文件第6页浏览型号S8980的Datasheet PDF文件第7页 
I M A G E S E N S O R  
CCD area image sensor  
S8980, S8981-02  
Front-illuminated FFT-CCDs for X-ray imaging  
S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega (1500 × 1000) pixels each of  
which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making  
S8980 very reliable even over a long-term operation. The scintillator coated on the FOP is optimized to have high X-ray sensitivity and high  
resolution (20 Lp/mm).  
S8981-02 is an easy-to-use X-ray imaging module using S8980, with added functions such as a cable assembly and X-ray trigger circuit. S8981-  
02 is advanced type for S8981 and adapted both AC and DC X-ray sources.  
Features  
Applications  
Sensor has X-ray monitoring photodiode  
Compactness  
General X-ray imaging  
Non-destructive inspection  
5.1 mm thickness excluding I/O connector part  
High dynamic range: 12 bit  
Long-term stability  
Intra-oral X-ray imaging in dental diagnosis  
For use under 100,000 shots  
(60 kVp, 30 mR X-ray irradiation)  
Resolution: 20 Lp/mm  
1500 (H) × 1000 (V) pixel format  
Pixel size: 20 × 20 µm  
Coupled with FOS for X-ray imaging  
100 % fill factor  
Low dark signal  
Low readout noise  
MPP operation  
AC/DC X-ray source adapted  
Selection guide  
Type No.  
Number of  
total pixels  
Number of  
active pixels  
Active area  
[mm (H) × mm (V)]  
Cooling  
S8980  
S8981-02  
Non-cooled  
1508 × 1002  
1500 × 1000  
30 × 20  
General ratings  
Parameter  
S8980  
S8981-02  
CCD structure  
Fill factor  
Full frame transfer  
100 %  
Number of active pixels  
Pixel size  
Active area  
Vertical clock phase  
Horizontal clock phase  
Output circuit  
Dimensional outline  
Reliability  
1500 (H) × 1000 (V)  
20 (H) × 20 (V) µm  
30 (H) × 20 (V) mm  
2 phase  
2 phase  
Emitter follower without load resistance  
35.5 (H) × 23.2 (V) mm 38.7 (H) × 26.3 (V) mm  
100,000 shots at 60 kVp, 30 m Roentgen  
Scintillator on 1.5 mm FOP  
Window  
Other  
MPP mode (low dark current operation), module (S8981-02)  
1

与S8980相关器件

型号 品牌 获取价格 描述 数据表
S8980_S10810_15 HAMAMATSU

获取价格

CCD area image sensors
S8981-02 HAMAMATSU

获取价格

Front-illuminated FFT-CCDs for X-ray imaging
S8981-02C HAMAMATSU

获取价格

CCD Sensor, 1500 Horiz pixels, 1000 Vert pixels, 5-11V, Rectangular, Surface Mount
S8982 HAMAMATSU

获取价格

CCD area image sensor Front-illuminated FFT-CCDs for X-ray imaging
S8984 HAMAMATSU

获取价格

CCD area image sensor Front-illuminated FFT-CCDs for X-ray imaging
S8984-02_15 HAMAMATSU

获取价格

Front-illuminated FFT-CCD for X-ray imaging
S8985-02 HAMAMATSU

获取价格

CCD area image sensor Front-illuminated FFT-CCDs for X-ray imaging
S8985-02C HAMAMATSU

获取价格

CCD Sensor, 1700 Horiz pixels, 1200 Vert pixels, 5-11V, Rectangular
S8986 HAMAMATSU

获取价格

CCD area image sensor Front-illuminated FFT-CCDs for X-ray imaging
S89R11AAC1-120 MACOM

获取价格

Bistable, Impulse Relay 15 and 20 Amp Industrial Rating Continuous Coil Rating