128Mb: x4, x8, x16
SDRAM 3.3V
AC ELECTRICAL CHARACTERISTICS: Vdd = 3.3V ± 10%V, Temp. = 25° to 70°C
AC CHARACTERISTICS
PARAMETER
Access time from CLK (positive edge) CL = 3
Access time from CLK (positive edge) CL = 2
Address hold time
Address setup time
CLK high level width
CLK low level width
Clock cycle time CL = 3
Clock cycle time CL = 2
CKE hold time
CKE setup time
CS#, RAS#, CAS#, WE#, DQM hold time
CS#, RAS#, CAS#, WE#, DQM setup time
Data-in hold time
-75A
MIN
-75A
MAX
5.4
-8A
MIN
-8A
MAX
6
SYMBOL
tAC
UNITS
ns
NOTES
tAC
tAH
tAS
tCH
tCL
tCK
tCK
tCKH
tCKS
tCMH
tCMS
tDH
N/A
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
0.8
1.5
2.5
2.5
7.5
N/A
0.8
1.5
0.8
1.5
0.8
1.5
1
2
3
3
10
1
2
1
2
1
2
Data-in setup time
tDS
ns
Data-out high impedance time
Data-out low impedance time
Data-out hold time
ACTIVE to PRECHARGE command period
AUTO REFRESH to ACTIVE command period
ACTIVE to READ or WRITE delay
Refresh period (4096 cycles)
PRECHARGE command period
ACTIVE bank A to bank B command period
Transition time
tHZ
tLZ
tOH
tRAS
tRC
tRCD
tREF
tRP
tRRD
tT
tWR
tXSR
tCCD
tCKED
tPED
9
16K
64
2
9
16K
64
2
ns
ns
ns
ns
ns
ns
ms
ns
ns
ns
ns
tCK
tCK
tCK
tCK
4
1
2.7
44
60
22.5
2
3
50
80
30
22.5
15
0.3
20
8
1
1
1
30
20
0.3
20
8
1
1
1
Write recovery time
3
Exit SELF REFRESH to ACTIVE command
READ/WRITE command to READ/WRITE command
CKE to clock disable or power down entry mode
CKE to clock enable or power down exit setup
1
2
2
AC ELECTRICAL CHARACTERISTICS: Vdd = 3.3V ± 10%V, Temp. = 25° to 70°C
AC CHARACTERISTICS
-75A
-75A
-8
-8
PARAMETER
DQM to input data delay
WRITE command to input data delay
Data-in to ACTIVATE command w/ Auto precharge
Data-in to precharge
SYMBOL
tDQD
tDWD
tDAL
MIN
MAX
MIN
MAX
UNITS
tCK
tCK
tCK
tCK
NOTES
0
0
5
2
0
0
5
2
1
1
3
tDPL
2, 3
Last data-in to precharge command
LOAD MODE REGISTER command to command
Data-out to high impedance from precharge
tRDL
tMRD
tROH
2
2
3
2
2
3
tCK
tCK
tCK
1
1
1
NOTES:
1. Clocks required specified by JEDEC functionality and not dependent on any timing parameter.
2. Timing actually specified by tCKS, clock(s) specified as a reference only at a minimum cycle rate.
3. Timing actually specified by tWR plus tRP clock(s) specified as a reference only at a minimum cycle rate.
4. tHZ defines the time at which the output achieves the open circuit condition; it is not a reference to Voh or Vol. The last valid data
element will meet tOH before going high-Z.
5. Based on tCK = 10ns for –8 and tCK = 7.5ns for –75a
PDF: 09005aef807827f6 / Source: 09005aef807825bd
128Mb SDRAM
Rev: 11/29/2004
SpecTek reserves the right to change products or
specifications without notice. Ó 2001, 2002, 2004 SpecTek
4