S-8240A Series
www.ablic.com
BATTERY PROTECTION IC FOR 1-CELL PACK
© ABLIC Inc., 2015-2019
Rev.2.7_00
The S-8240A Series is a protection IC for lithium-ion / lithium polymer rechargeable batteries and includes high-accuracy
voltage detection circuits and delay circuits.
The S-8240A Series is suitable for protecting 1-cell lithium-ion / lithium polymer rechargeable battery packs from overcharge,
overdischarge, and overcurrent.
Features
• High-accuracy voltage detection circuit
Overcharge detection voltage
Overcharge release voltage
3.500 V to 4.600 V (5 mV step)
3.100 V to 4.600 V*1
2.000 V to 3.400 V (10 mV step)
2.000 V to 3.400 V*2
0.015 V to 0.200 V (5 mV step)
0.065 V to 0.500 V (25 mV step)*3
−0.200 V to −0.015 V (5 mV step)
Accuracy 20 mV
Accuracy 50 mV
Accuracy 50 mV
Accuracy 100 mV
Accuracy 5 mV
Accuracy 40 mV
Accuracy 5 mV
Overdischarge detection voltage
Overdischarge release voltage
Discharge overcurrent detection voltage
Load short-circuiting detection voltage
Charge overcurrent detection voltage
• Detection delay times are generated only by an internal circuit (external capacitors are unnecessary).
• 0 V battery charge function is selectable:
• Power-down function is selectable:
• Release condition of discharge overcurrent status is selectable:
• Release voltage of discharge overcurrent status is selectable:
Available, unavailable
Available, unavailable
Load disconnection, charger connection
VRIOV, VDIOV
• High-withstand voltage:
• Wide operation temperature range:
• Low current consumption
During operation:
VM pin and CO pin: Absolute maximum rating 28 V
Ta = −40°C to +85°C
1.5 μA typ., 3.0 μA max. (Ta = +25°C)
50 nA max. (Ta = +25°C)
During power-down:
During overdischarge:
500 nA max. (Ta = +25°C)
• Lead-free (Sn 100%), halogen-free
*1. Overcharge release voltage = Overcharge detection voltage − Overcharge hysteresis voltage
(Overcharge hysteresis voltage can be selected from a range of 0 V to 0.4 V in 50 mV step.)
*2. Overdischarge release voltage = Overdischarge detection voltage + Overdischarge hysteresis voltage
(Overdischarge hysteresis voltage can be selected from a range of 0 V to 0.7 V in 100 mV step.)
*3. Load short-circuiting detection voltage = Discharge overcurrent detection voltage + 0.025 × n
(n can be selected from any integer value greater or equal to 2)
Applications
• Lithium-ion rechargeable battery pack
• Lithium polymer rechargeable battery pack
Packages
• SOT-23-6
• SNT-6A
• HSNT-6 (1212)