60W Single Output Switching Power Supply
S-60 series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 77KHz
2 years warranty
SPECIFICATION
MODEL
S-60-5
S-60-12
S-60-15
S-60-24
DC VOLTAGE
5V
12V
15V
24V
RATED CURRENT
CURRENT RANGE
RATED POWER
12A
5A
4A
2.5A
0 ~ 12A
60W
0 ~ 5A
0 ~ 4A
60W
0 ~ 2.5A
60W
60W
RIPPLE & NOISE (max.) Note.2 120mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 2.0%
120mVp-p
150mVp-p
13.5 ~ 16.5V
1.0%
150mVp-p
21.6 ~ 26.4V
1.0%
OUTPUT
10.8 ~ 13.2V
4.75 ~ 5.5V
1.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
0.5%
0.5%
0.5%
0.5%
1.0%
0.5%
0.5%
0.5%
300ms, 50ms/230VAC
800ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
80ms/230VAC
85 ~ 264VAC
47 ~ 63Hz
73%
12ms/115VAC at full load
120 ~ 370VDC
FREQUENCY RANGE
EFFICIENCY(Typ.)
76%
77%
79%
INPUT
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
2A/115VAC
1A/230VAC
COLD START 20A/115VAC
<3.5mA / 240VAC
40A/230VAC
105 ~ 150% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
13.8 ~ 16.2V 17.25 ~ 20.25
PROTECTION
27.6 ~ 32.4V
5.75 ~ 6.75V
OVER VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
ENVIRONMENT
-20 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50
)
TEMP. COEFFICIENT
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1012, UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
SAFETY &
ISOLATION RESISTANCE
EMC
(Note 4)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
316.2K hrs min. MIL-HDBK-217F (25
159*97*38mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
0.51Kg; 24pcs/13.1Kg/0.7CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:S-60-SPEC 2007-09-19