200W Single Output Switching Power Supply
S-201 series
■ Features :
$AC input range selectable by switch
$Protections: Short circuit / Overload / Over temperature
$Cooling by free air convection
$100% full load burn-in test
$Compact size, light weight
$Fixed switching frequency at 25KHz
$Low cost
$High reliability
$1 year warranty
SPECIFICATION
MODEL
S-201-5
S-201-7.5
S-201-12
S-201-13.5
S-201-15
S-201-24
S-201-27
S-201-48
DC VOLTAGE
5V
7.5V
12V
13.5V
15V
24V
27V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
40A
26.5A
16.5A
14.7A
13A
8.3A
7.4A
4.2A
0 ~ 40A
200W
0 ~ 26.50A
198.75W
150mVp-p
6 ~ 9V
2.0%
0 ~ 16.5A
198W
0 ~ 14.7A
198.45W
150mVp-p
12 ~ 15V
1.0%
0 ~ 13A
198W
0 ~ 8.3A
199.2W
150mVp-p
20 ~ 26.4V
1.0%
0 ~ 7.4A
199.8W
200mVp-p
26 ~ 32V
1.0%
0 ~ 4.2A
201.6W
240mVp-p
41 ~ 56V
1.0%
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 2.0%
150mVp-p
10 ~ 13.2V
1.0%
150mVp-p
13.5 ~ 18V
1.0%
OUTPUT
4.5 ~ 5.6V
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
0.5%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
200ms, 100ms at full load
24ms at full load
VOLTAGE RANGE
90 ~ 132VAC / 180 ~ 264VAC by switch
47 ~ 63Hz
254 ~ 370VDC
80%
FREQUENCY RANGE
EFFICIENCY (Typ.)
74%
79%
2A/230VAC
45A/230VAC
80%
81%
83%
83%
84%
INPUT
3.6A/115VAC
45A/115VAC
<3.5mA / 240VAC
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
5.75 ~ 6.75V 9.4 ~ 10.9V 13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V 27.6 ~ 32.4V 33.7 ~ 39.2V 57.6 ~ 67.2V
OVERLOAD
OVER VOLTAGE
PROTECTION
Protection type : Shut down o/p voltage, re-power on to recover
≧90℃(RTH3) detect on inside ambient temperature
OVER TEMPERATURE
WORKING TEMP.
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +50℃ (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +85℃, 10 ~ 95% RH
ENVIRONMENT
0.03%/℃ (0 ~ 50℃)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
Design refer to UL1950
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
SAFETY &
EMC
EMI CONDUCTION & RADIATION Design refer to FCC Part15 J Conduction Class A
MTBF
271.9K hrs min. MIL-HDBK-217F (25℃)
215*115*50mm (L*W*H)
OTHERS
NOTE
DIMENSION
PACKING
0.93Kg; 12pcs/12Kg/0.92CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
File Name:S-201-SPEC 2007-10-25