General Purpose Relays
PCB Relays
SCHRACK
Miniature Power PCB RYII & RYII Reflow Solderable
n
n
n
n
n
n
n
1 pole 8A, 1 form C (CO) or 1 form A (NO) or 1 form B (NC) contact
Low component height 12.3mm
5kV/8mm coil-contact
Reinforced insulation (protection class II)
Pinnings: 3.2mm and 5mm
Reflow-solderable version
Especially suitable for resistive and inductive loads on
form A (NO) and form B (NC) contacts
Plastic materials according to IEC 60335-11) (domestic appliances)
n
Typical applications
F0142-E
heating control, interface technology, domestic appliances, timers,
temperature control
V Z
1) not available as reflow-solderable version
Approvals
VDE REG.-Nr. 5358, UL E214025
Technical data of approved types on request
Coil Data
Coil voltage range
Operative range, IEC 61810
5 to 60VDC
2
Contact Data
Coil versions, DC coil
Contact arrangement
1 form C (CO) or
1 form A (NO) or
1 form B (NC)
250VAC
Coil
code
Rated
voltage
VDC
5
6
9
12
24
48
60
Operate
voltage
VDC
3.5
4.2
6.3
Release
voltage
VDC
0.5
0.6
0.9
1.2
2.4
4.8
6.0
Coil
Rated coil
power
mW
resistance
Ω 10ꢀ
112
162
320
627
2350
9391
14000
Rated voltage
Max. switching voltage
Rated current
Breaking capacity max.
Contact material
Frequency of operation, with/without load
Operate/release time max.
Bounce time max., form A/form B
005
006
009
012
024
048
060
223
222
253
230
245
245
257
400VAC
8A
2000VA
8.4
AgNi0.15, AgSnO2
6/1200min-1
9/5ms
16.8
33.6
42.0
All figures are given for coil without pre-energization, at ambient temperature +23°C
Other coil voltages on request
6/10ms
Contact ratings
Type
Contact
Load
Cycles
IEC61810
RY531 A (NO)
RY211 A (NO)
RY211 A (NO)
UL508
RY211 A/B (NO/NC) 10A, 250VAC, general purpose, 70°C
RY211 A (NO) 1/2hp, 240VAC, 85°C
RY211 A/B (NO/NC) B300, 70°C
EN60730-1
RY211 A/B (NO/NC) 6(4)A, 250VAC, 85°C
8A, 250VAC, 70°C
8A, 250VAC, 70°C
8A, 250VAC, 70°C
100x103
75x103
50x103
30x103
30x103
6x103
100x103
100x103
RY211 A (NO)
Mechanical endurance, DC coil
8(4)A, 250VAC, 75°C
30x106 operations
Insulation Data
Initial dielectric strength
between open contacts
between contact and coil
Clearance/creepage
1000Vrms
5000Vrms
between contact and coil
Material group of insulation parts
Tracking index of relay base
reflow-solderable version
≥8/8mm
IIIa
PTI250
PTI175
1
04-2011, Rev. 0411
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company