General Purpose Relays
SCHRACK
Miniature Power PCB RY II & RY II reflow-solderable
I
I
I
I
I
I
I
I
I
1 pole 8 A, 1 CO or 1 NO or 1 NC contact
Low component height 12.3 mm
5 kV / 8 mm coil-contact
Reinforced insulation (protection class II)
Pinnings: 3.2 and 5 mm
reflow-solderable version
Sockets with PCB-type terminals
Especially suitable for resistive and inductive loads on NO and NC contacts
Plastic materials according to IEC60335-1 (domestic appliances)
(not at reflow-solderable version)
F0142-F
I
RoHS compliant (Directive 2002/95/EC) as per product date code 0403
Applications: heating control, interface technology, domestic appliances, timers,
temperature control
Approvals
V
REG.-Nr. 5358,
Z
E214025
Technical data of approved types on request
Contact data
Contact configuration
1 CO or 1NO or 1NC
single contact
micro disconnection
8 A
Contact set
Type of interruption
Rated current
Rated voltage / max. switching voltage AC
Maximum breaking capacity AC
Contact material
250/400 VAC
2000 VA
AgNi0,15, AgSnO2, AgCdO
30x106 cycles
6 / 1200 min-1
Mechanical endurance
Rated frequency of operation with / without load
Contact ratings
Type
Load
Cycles
RY**1***
RY**1***
NO, 8 A, 250 VAC, resistive, 70°C
NC, 8 A, 250 VAC, resistive, 70°C
8 A, 30 VDC, UL 508
1x105
5x104
3 x104
3 x104
RY**(0,1,2)***
RY**(0,1,2)***
RY**(0,1,2)***
RY**(0,1,2)***
RY**(0)***
RY**(0,1,2)***
RY*** ***
0,28 A, 250 VDC, UL 508
1/2 HP, 240 VDC, UL 508
1/4 HP, 120 VDC, UL 508
8 A, 415 VAC, resistive, UL 508
Pilot duty - B300, UL 508
CO, 8 A, 250 VAC, resistive, 70°C
6(4)A, 250 VAC, 85°C, EN60730
3
6 x10
6000
3
5x10
RY**1 ***
1x105
Coil data
Rated coil voltage range DC coil
Coil power DC coil
5...60 VDC
typ. 220 mW
2
Operative range
Coil versions, DC-coil
Coil
Rated
Operate
voltage
VDC
3,5
Release
voltage
VDC
0,5
Coil
resistance
Ohm
112+10%
162+10%
320+10%
627+10%
2350+10%
9391+10%
14000+10%
Rated coil
power
mW
code
voltage
VDC
5
005
006
009
012
024
048
060
223
6
4,2
0,6
222
9
6,3
8,4
16,8
33,6
42,0
0,9
253
12
24
48
60
1,2
230
2,4
245
4,8
245
6,0
257
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
1
Datasheet
Rev. HC1
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Issued 2008/03
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
www.tycoelectronics.com
www.schrackrelays.com
Specifications subject to
change.