ECONOLINE - DC/DC-Converter
RY-0505SCL/DCL Ser., 1W, SIP7, Regul., Current Limit Protection (Single & Dual Output)
Selection Guide
Part
Number
SIP 7
Input
Voltage
(VDC)
Output
Voltage
(VDC)
Ouput
Current
(mA)
Input Current
Full Load No Load
Efficiency
(mA)
(%)
57
6±
62
59
62
63
62
63
63
RY-0505SCL/DCL
RY-05±2SCL/DCL
RY-05±5SCL/DCL
RY-±205SCL/DCL
RY-±2±2SCL/DCL
RY-±2±5SCL/DCL
RY-2405SCL/DCL
RY-24±2SCL/DCL
RY-24±5SCL/DCL
5
5/±5
±2/±±2
±5/±±5
5/±5
200/±±00
84/±42
350
330
322
±4±
±34
±32
67
20
32
32
±0
±5
±5
6
5
Features
5
67/±34
● Internal SMD Technology
● Short Circuit Protection: Current Limit
● Isolation ±kVDC
● No External Components Required
● Regulated Output
±2
±2
±2
24
24
24
200/±±00
84/±42
±2/±±2
±5/±±5
5/±5
67/±34
200/±±00
84/±42
±2/±±2
±5/±±5
66
6
● UL94V-0 Package Material
67/±34
66
6
Specifications (Core Operating Area) and Operating Temperature / Derating-Graph
Input Voltage
±±0%
Voltage Setpoint Accuracy
Temperature Coefficient
Short Circuit Protection
Input Filter
±2%
2.0
±.5
±.0
0,5
±0.03%/ꢀC
Current Limit Protection
Capacitor Type
±0.5% max.
Line Voltage Regulation
Load Voltage Regulation (±0% to ±00% full load)
Ripple and Noise (20MHz BW)
Efficiency at Full Load
Isolation Voltage
±0.5% max.
Safe Operating Area
±00mVp-p max.
50% min.
0
±.000VDC min.
±00kHz min.
-25
0
50
±00
±50
Switching Frequency at Full Load
Operating Temperature
Storage Temperature
70
Operating Temperature ˚C
±25
-25ꢀC to +70ꢀC (see Graph)
-55ꢀC to +±00ꢀC
80pF max.
Capacitance
Package Style and Pinning (mm)
±9.60
3rd angle
projection
7 PIN SIP Package and Recommended Footprint Details
7.±0
Single Output
Dual Output
Pin Connections
RY-0505DCL
RY-0505SCL
RECOM
****
RY-0505DCL
RECOM
****
RECOM
****
±0.±4
0.5± typ.
0.5± typ.
Pin #
Single
+Vin
Dual
±
2
5
6
7
+Vin
–Vin
–Vin
±
2
5
7
±
2
5
6 7
2.54
–Vout
No Pin
+Vout
–Vout
Com
3.8±min.
+Vout
ø
ø
±.00 +0.±5/–0
±.00 +0.±5/–0
2.54
2.54
0.25
0.9
2.0
±
2
5 6 7
±5.24
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
2.54
2.54
EC 44
August 2002
www.recom-international.com