General Purpose Relays
SCHRACK
Interface Power Relay RT
I
I
I
I
I
I
I
1 pole 12 / 16 A, 2 pole 8 A, 1 CO contact or 2 CO contacts
DC- or AC coil
Sensitive coil 400 mW
Reinforced insulation, protection class II (VDE 0700)
5 kV / 10 mm coil-contact
1 pole 12 A with 3.5 or 5 mm pinning
Recycleable packaging
Applications
F0269-C
Panel boards, mechanical engineering
Approvals
V
REG.-Nr. 6106,
Z
E214025
Technical data of approved types on request
Contact data
1-pole
2-pole
Contact configuration
1 CO
2 CO
Contact set
Type of interruption
Rated voltage / max. switching voltage AC
Rated current
Maximum breaking capacity AC
Limiting making capacity,max 4 s, df 10%
Contact material
Rated frequency of operation DC coil with / without load
AC coil with / without load
Operate- / release time DC coil
Bounce time DC coil, NO / NC contact
single contact
micro disconnection
240 / 400 VAC
12 / 16 A
8 A
2000 VA
15 A
3000 / 4000 VA
25 / 30 A
AgNi 90/10
6 / 1200 min-1
6 / 600 min-1
max 8 / 6 ms
max 4 / 6 ms
max 10 / 5 ms
max 4 / 9 ms
Contact ratings
Type
Contact Load
Ambient
Cycles
temp. [°C]
IEC 61810
RT314 DC-coil NO
RT314 AC-coil NO
RT314 AC-coil CO
RT424 AC coil CO
UL 508
10 A, 400 VAC, cosϕ=1
85°C
70°C
70°C
70°C
150x103
50x103
10x103
30x103
16 A, 250 VAC, cosϕ=1
16 A, 250 VAC, cosϕ=1
8 A, 250 VAC, cosϕ=1
RT314
RT314
RT314
RT314
NO
NO
NC
NO
16 A, 250 VAC, general purpose, DF: 10% 85°C
50x103
6x103
6x103
1x103
6x103
30x103
1x103
6x103
A300
40°C
40°C
40°C
85°C
85°C
85°C
85°C
B300
240 VAC, 1 hp
RT424 DC coil NO / NC 8 A, 30 VDC, general purpose
RT424 DC coil NO
RT424 DC coil NO / NC motor, 1/2 hp, 240 VAC
RT424 DC coil NO / NC pilot duty, B300, R300
EN60730-1
RT314 DC-coil NO
RT424 DC coil NO / NC 6(2) A, 250 VAC
10 A, 250 VAC, general purpose
12(2) A, 250 VAC
85°C
85°C
100x103
100x103
Coil data
Rated coil voltage range DC coil
AC coil
5...110 VDC
24...230 VAC
Operative range to IEC 61810
Coil insulation system according UL1446
2
class F
1
Datasheet Rev. HK1
Issued 2008/11
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
Product specification
processing information only
in the ‘Schrack’ section.
otherwise specified and are
shown for reference purposes
only.
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
to be used together with the
'Definitions' section in the cat-
alogue or at schrackrelays.com
Specifications subject to
change.