● 1kVDC & 2kVDC Isolation
● UL94V-0 Package Material
● No Heatsink Required
● No External Components Required
● Toroidal Magnetics
● Optional Continuous Short Circuit Protected
ECONOLINE
Features
DC/DC-Converter
Regulated
Converters
RSZ/P
Series
Selection Guide
Part
Number
Input
Voltage
(VDC)
Output
Voltage
(VDC)
Output
Current
(mA)
SMD
2kVDC
1 Watt
SMD Miniature
Isolated
RSZ-xxxx
(H) 3.3, 5, 6, 7, 8, 9, 10, 11, 12, 13,
14, 15, 16, 17, 18, 19, 20, 21,
22, 23, 24, 25, 26, 27, 28
3, 4, 5, 6, 7, 8, 9,
10, 11, 12, 13, 14
Depending
on
Output Voltage
Standard
With Short Circuit Protection
RSZ-xx03/P (H) 3.3, 5, 6, 7, 8, 9, 10, 11, 12, 13,
14, 15, 16, 17, 18, 19, 20, 21,
3
3.3
4.85
5
200
200
200
200
22, 23, 24, 25, 26, 27, 28
Single Output
RSZ-xx3.3/P (H) 3.3, 5, 6, 7, 8, 9, 10, 11, 12, 13,
14, 15, 16, 17, 18, 19, 20, 21,
22, 23, 24, 25, 26, 27, 28
RSZ-xx4.85/P (H) 3.3, 5, 6, 7, 8, 9, 10, 11, 12, 13,
14, 15, 16, 17, 18, 19, 20, 21,
22, 23, 24, 25, 26, 27, 28
RSZ-xx05/P (H) 3.3, 5, 6, 7, 8, 9, 10, 11, 12, 13,
14, 15, 16, 17, 18, 19, 20, 21,
22, 23, 24, 25, 26, 27, 28
xx = Input Voltage
Ordering Example: RSZ-0514 (5VDC Input, 14VDC Output)
RSZ-244.8/HP (with 24VDC input, 4.85VDC Output, 2kVDC Isolation and
Continuous Short Circuit Protection)
Specifications (Core Operating Area)
Input Voltage Range
5ꢀ
Output Voltage Accuracy
Line Voltage Regulation
Load Voltage Regulation
Output Ripple and Noise (at 20MHz BW)
Operating Frequency
2ꢀ
1ꢀ max.
1ꢀ max.
100mVp-p max.
Derating-Graph
(Ambient Temperature)
20kHz min. / 50kHz typ. / 85kHz max.
50ꢀ min. / 60ꢀ typ.
Efficiency at Full Load
No Load Power Consumption
134mW min. / 217mW typ. / 350mW max.
Isolation Voltage
(tested for 1 second)
1000VDC min.
Rated Working Voltage
(long term isolation)
see Application Notes
100
80
Isolation Voltage
Rated Working Voltage
H-Suffix
H-Suffix
(tested for 1 second)
(long term isolation)
2000VDC min.
see Application Notes
60
Isolation Capacitance
Isolation Resistance
70pF typ.
Safe Operating Area
40
20
10 GΩ min.
Short Circuit Protection
P-Suffix
1 Second
Continuous
0
85
100 150
70
-40
0
50
Operating Temperature Range (free air)
Storage Temperature Range
-40°C to +70°C (see Graph)
-55°C to +125°C
Operating Temperature °C
Reflow Temperature ROHS compliant (for more details see Application Notes) 245°C (30 sec) max.
Relative Humidity
95ꢀ RH
continued on next page
July-2006
26
www.recom-international.com