2000W Single Output Power Supply
RSP-2000 series
Features :
Universal AC input / Full range
Built-in 5V/0.3A, 12V/0.8A auxiliary power
Built-in active PFC function, PF>0.97
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC fan with fan speed control
Output voltage can be trimmed between 40~115% of the rated output voltage
High Power density 21.4W/inch3
1U low profile 41mm
Active current sharing up to 8000W(3+1)
Built-in remote ON-OFF control
Built-in remote sense function
DC OK signal, OTP alarm signal
3 years warranty
SPECIFICATION
MODEL
RSP-2000-12
RSP-2000-24
RSP-2000-48
DC VOLTAGE
RATED CURRENT
12V
24V
48V
100A
80A
42A
CURRENT RANGE
RATED POWER
0 ~ 100A
1200W
0 ~ 80A
1920W
200mVp-p
21 ~ 28V
1.0%
0 ~ 42A
2016W
300mVp-p
42 ~ 56V
1.0%
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE ADJ. RANGE 10.5 ~ 14V
VOLTAGE TOLERANCE Note.3 2.0%
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1500ms, 60ms/230VAC at full load
16ms/230VAC at 75% load
10ms/230VAC at full load
Note.5 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
47 ~ 63Hz
0.97/230VAC at full load
87%
90.5%
92%
INPUT
13A/115VAC
7A/230VAC
16A/115VAC
10A/230VAC
16A/115VAC
10A/230VAC
Note.5
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
COLD START 50A
<2mA / 240VAC
105 ~ 125% rated output power
OVERLOAD
Protection type : Constant current limiting, unit will shut down o/p voltage after 5 sec. re-power on to recover
14.7 ~ 17.5V
29.5 ~ 35V 57.6 ~ 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
80 (TSW1) detect on heatsink of power bridge 75 (TSW2) detect on heatsink of o/p diode
OVER VOLTAGE
OVER TEMPERATURE
PROTECTION
5
5
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
5V @ 0.3A, 12V @ 0.8A
AUXILIARY POWER
By electrical signal or dry contact Power ON:open Power OFF:short, refer to function manual
Compensate voltage drop on the load wiring up to 0.5V, refer to function manual
The isolated TTL signal out, refer to function manual
REMOTE ON/OFF CONTROL
FUNCTION
REMOTE SENSE
DC OK SIGNAL
Adjustment of output voltage, possible between 40 ~ 115% of rated output, refer to function manual
-35 ~ +70 (Refer to "Derating Curve")
OUTPUT VOLTAGE TRIM
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
-40 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
TEMP. COEFFICIENT
VIBRATION
0.03%/ (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY &
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC
(Note 4)
Compliance to EN55022 (CISPR22) Conduction Class B, Radiation Class A ; EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
46.3Khrs min. MIL-HDBK-217F (25
)
OTHERS
NOTE
DIMENSION
295*127*41mm (L*W*H)
1.95Kg; 6pcs/12.7Kg/1.15CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. Under parallel operation ripple of the output voltage may be higher than the SPEC at light load condition. It will go back to normal ripple level once the
output load is more than 5%.
File Name:RSP-2000-SPEC 2011-12-27